Description | GW Instek introduces the brand new high precision LCR meter - LCR-6000 series, which, with five models, has a test frequency range extending from 2kHz/20kHz/100kHz/200kHz/300kHz (maximum) and with 0.05% basic accuracy. The compact size design, 2U height and 1/2 rack, is one of the practical features of the series which is the optimum space saver suitable for either bench top or system rack. The compacted LCR-6000 series with abundant features is absolutely the excellent tool for R&D, production test, IQC, etc. on implementing each test stages for passive components. | 350W DC Linear Power Supply 0-35V, 0-10A
0-35V, 0-10A
0.01% High Regulation
Constant Voltage and Constant Current Operation
Internal Select for Continuous or Dynamic Load
Low Ripple and Noise
Overload and Reverse Polarity Protection
3 1/2 Digit 0.5" LED Display | 180W, 2ch Output DC Programmable Power Supply
4 Outputs for GPD-4303S
High Resolution Display 1mV / 1mA (GPD-X303S)
CH1/CH2 Output: 30V / 3A
CH3 Selectable Output: 5V/3A ; 5.001V-10V /1A (GPD-4303S)
CH4 Output: 5V / 1A (GPD-4303S)
Auto Series / Parallel Tracking Mode
Digital Panel ControlRotary Encoder Switch and Rubber Key with Backlight
4 Sets SAVE / RECALL panel setting
User Friendly Operation, Coarse and Fine Voltage Control
Warning Buzzer
Output On / Off Switch
USB Device for Remote Control (Baud Rate 115200 bps Maximum)
Free downloadable PC software
Smart Cooling Fan with Low Noise
Safety Design: Reverse Polarity, Overload Protection | Hybrid Linear, Low noise, 0-20V/0-36A, 720W
- Output Voltage Rating: 20V
- Output Power: 720W
- Low Ripple and Noise (0.5mVrms/ 10mArms)
- Fast transition recovery time (100us)
- Maximum 2 units in series connections or 3 units in parallel connections
- Select the setting digits for voltage and current (coarse/ fine volume control)
- Panel Lock Function
- 3 set of preset function
- Output off timer function (Range: 1min to 1000hours & 59mins)
- CC priority function (prevent overshoot & inrush current)
- Sequence function of PC editing (Max.: 1000 steps/ Min. step period: 50ms)
- Protection: OVP, UVP, OCP, remote sensing (Terminal open)
- External Analog Control Function
- PC Remote Interface (Standard): RS-232; (Optional): GPIB / USB / LAN
- CE Compliance
| 180W DC Linear Power Supply 0-18V, 0-10A DIGITAL
0.01% High Resolution
Constant Voltage and Constant Current Operation
Internal Select for Continuous or Dynamic Load
Low Ripple and Noise
Overload and Reverse Polarity Protection
3½ Digit 0.5" LED Displays Showing Voltage and Current | Hybrid Linear, Low noise, 0-20V/0-18A, 360W
- Output Voltage Rating: 20V
- Output Power: 360W
- Low Ripple and Noise (0.5mVrms/ 10mArms)
- Fast transition recovery time (100us)
- Maximum 2 units in series connections or 3 units in parallel connections
- Select the setting digits for voltage and current (coarse/ fine volume control)
- Panel Lock Function
- 3 set of preset function
- Output off timer function (Range: 1min to 1000hours & 59mins)
- CC priority function (prevent overshoot & inrush current)
- Sequence function of PC editing (Max.: 1000 steps/ Min. step period: 50ms)
- Protection: OVP, UVP, OCP, remote sensing (Terminal open)
- External Analog Control Function
- PC Remote Interface (Standard): RS-232; (Optional): GPIB / USB / LAN
- CE Compliance
|
Additional information |
Weight |
8 lbs |
Dimensions |
12 × 12 × 6 in |
|
Weight |
15 lbs |
Dimensions |
18 × 12 × 10 in |
|
Weight |
15 lbs |
Dimensions |
18 × 12 × 10 in |
|
Weight |
15 lbs |
Dimensions |
18 × 12 × 10 in |
|
Weight |
15 lbs |
Dimensions |
18 × 12 × 10 in |
|
Weight |
15 lbs |
Dimensions |
18 × 12 × 10 in |
|