In Stock

Amprobe SC-3500 4? Signal Clamp for AT-3500

Available for Quote

View List

Description

The Amprobe SC-3500 4? Signal Clamp for AT-3500 attaches around a buried metallic pipe, cable, or wire to induce a transmitted signal into the feature for active location and tracing. It does not require direct contact with metal to transmit the signal and can transmit signal through insulation on wires and into cable and wire bundles, providing more accurate tracing than locating with just a receiver and transmitter. Accommodates conductors up to 4? in diameter. Transmits a 33 kilohertz (kHz) frequency supplied by the T-3500 Transmitter (included in the AT-3500 kit).

Quick Comparison

SettingsAmprobe SC-3500 4? Signal Clamp for AT-3500 removeAmprobe AT-6000-T Transmitter removeAmprobe AMB-55 Industrial High-Voltage Insulation Tester removeAmprobe AT-7020 Advanced Wire Tracer Kit removeAmprobe AMB-110 Industrial High-Voltage Insulation Tester removeAmprobe TMA-21HW Hotwire Anemometer with Temperature remove
Image
SKUN_Amprobe SC-3500N_Amprobe AT-6000-TN_Amprobe AMB-55N_Amprobe AT-7020N_Amprobe AMB-110_EBN_Amprobe TMA-21HW
Rating
PriceAvailable for QuoteAvailable for QuoteAvailable for QuoteAvailable for QuoteAvailable for QuoteAvailable for Quote
Stock
Availability
Add to cart

Add to Cart

Add to Cart

Add to Cart

Add to Cart

Add to Cart

Add to Cart

Description
ContentThe Amprobe SC-3500 4? Signal Clamp for AT-3500 attaches around a buried metallic pipe, cable, or wire to induce a transmitted signal into the feature for active location and tracing. It does not require direct contact with metal to transmit the signal and can transmit signal through insulation on wires and into cable and wire bundles, providing more accurate tracing than locating with just a receiver and transmitter. Accommodates conductors up to 4? in diameter. Transmits a 33 kilohertz (kHz) frequency supplied by the T-3500 Transmitter (included in the AT-3500 kit).The AT-6000-T Transmitter works on Energized and De-energized circuits up to 600 V AC/DC in Category I through Category III electrical environments and features high signal, low signal, and loop modes. The Breaker Identification feature eliminates confusion of multiple false positives, common with older technology tracing tools, by identifying the one correct breaker or fuse with the highest recorded signal.Eliminate downtime, predict the lifetime of equipment and reduce safety hazards with the Amprobe AMB-55 Insulation Resistance Tester that tests voltage and step voltage to 5,500 V. You can accurately test cables, transformers, motors, surge arrestors and generators in noisy environments such as high voltage switchyards. It also boasts built-in noise rejection filters and shielded test leads to provide high EMI immunityThe AT-7020 Advanced Wire Tracer kit includes the AT-7000-R Receiver and the AT-7000-T Transmitter. The Receiver includes Amprobe?s patented Smart Sensor feature to instantly display the location and orientation of energized wires in walls, floors, and ceilings. You can clearly see the direction of the wire on the large, bright TFT LCD full color display. In hard-to-reach areas, you can use the Receiver?s Tip Sensor to trace wires in corners, tight spaces and junction boxes. The Transmitter offers two automatically-selected frequency modes for optimal tracing on energized and de-energized circuits, and three power modes (high, low, clamp) for a variety of environments. The breaker mode?s Scan and Locate feature identifies the one correct breaker or fuse with the highest recorded signal, thus eliminating the confusion of multiple false positives common with older technology tracing tools. So whether you?re a novice user or an expert, this Amprobe circuit tracer kit will help you get the job done fast.Eliminate downtime, predict the lifetime of equipment and reduce safety hazards with the Amprobe AMB-110 Insulation Resistance Tester that tests voltage and step voltage to 10,000 V. You can accurately test cables, transformers, motors, surge arrestors and generators in noisy environments such as high voltage switchyards. It also boasts built-in noise rejection filters and shielded test leads to provide high EMI immunity.The Amprobe TMA-21HW Hotwire anemometer technology eliminates the use of bearings and rotating parts. When compared to standard bearing type probes, the compact Amprobe hotwire sensor is more reliable (no mechanical moving parts) and allows for easier access to duct and confined spaces. The Amprobe TMA-21HW Hotwire anemometer measures air flow volume and velocity, it features a telescopic probe for positioning the sensor, and is used by HVAC/R technicians to measure wind flow and temperature in air conditioning systems.
Weight21155152
Dimensions9.84 × 9.84 × 9.84 in9.5 × 6.5 × 1.75 in17.3 × 5.8 × 13 in17.3 × 14.3 × 8.8 in14 × 10 × 15 in14 × 11.4 × 3.7 in
Additional information
Weight 2 lbs
Dimensions 9.84 × 9.84 × 9.84 in
Weight 1 lbs
Dimensions 9.5 × 6.5 × 1.75 in
Weight 15 lbs
Dimensions 17.3 × 5.8 × 13 in
Weight 5 lbs
Dimensions 17.3 × 14.3 × 8.8 in
Weight 15 lbs
Dimensions 14 × 10 × 15 in
Weight 2 lbs
Dimensions 14 × 11.4 × 3.7 in