Chroma 63802 Programmable AC Load 1.8KVA/18A/350VAC
Available for Quote
The Chroma 63800 Electronic Loads can simulate a variety of load conditions under high crest factor and varying power factors with real time compensation even when the voltage waveform is distorted. This unique feature provides real world simulation capabilities and prevents overstressing the instrument resulting in reliable and unbiased test results.Chroma?s 63800 AC & DC Electronic Load is designed for both AC & DC Load Simulations
Out of stock
Quick Comparison
Settings | Chroma 63802 Programmable AC Load 1.8KVA/18A/350VAC remove | GW Instek PEL-2020 Programmable DC Electronic Load Dual Channel Module, 1~80V, 20A, 100W remove | GW Instek PEL-2004A 4-Slot Programmable DC Electronic Load Mainframe remove | Agilent 60502B 300 Watt DC Electronic Load Module (3~60V, 60A, 300W) remove | Agilent 60501A 60 V, 30 A DC Electronic Load Module, 150W remove | Agilent 60501B 150 Watt DC Electronic Load Module remove | ||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Image | ![]() | ![]() | ![]() | ![]() | ![]() | ![]() | ||||||||||||||||||||||||
SKU | Chroma 63802 | N_GW Instek PEL-2020A | N_GW Instek PEL-2004A | Agilent 60502B | Agilent 60501A | Agilent 60501B | ||||||||||||||||||||||||
Rating | ||||||||||||||||||||||||||||||
Price | Available for Quote | Available for Quote | Available for Quote | Available for Quote | Available for Quote | Available for Quote | ||||||||||||||||||||||||
Stock | Out of stock | 1 in stock | 1 in stock | 1 in stock | ||||||||||||||||||||||||||
Availability | Out of stock | 1 in stock | 1 in stock | 1 in stock | ||||||||||||||||||||||||||
Add to cart | ||||||||||||||||||||||||||||||
Description | The Chroma 63800 Electronic Loads can simulate a variety of load conditions under high crest factor and varying power factors with real time compensation even when the voltage waveform is distorted. This unique feature provides real world simulation capabilities and prevents overstressing the instrument resulting in reliable and unbiased test results.Chroma?s 63800 AC & DC Electronic Load is designed for both AC & DC Load Simulations | The PEL-2000A Series includes two types of mainframes and 4 types of load modules to accommodate users' requirements in a flexible manner. Any load module combination can be used with a mainframe to tailor a test system based on the number of channels, and the maximum load power, voltage and current of each channel. Multiple loads can be connected in parallel to provide a higher-power load to test higher power supply outputs. This flexibility significantly reduces the investment needed for future projects that have different power requirements. The PEL-2004A is a 4-slot mainframe with a master control unit to hold 4 load modules, while PEL-2002A is a 2-slot mainframe with master control unit to hold 2 load modules. When the PEL-2004A is configured with 4 load modules rated at 350W each, the PEL-2000A series is able to sink up to 1.4kVA of power. | The PEL-2000A Series includes two types of mainframes and 4 types of load modules to accommodate users' requirements in a flexible manner. Any load module combination can be used with a mainframe to tailor a test system based on the number of channels, and the maximum load power, voltage and current of each channel. Multiple loads can be connected in parallel to provide a higher-power load to test higher power supply outputs. This flexibility significantly reduces the investment needed for future projects that have different power requirements. The PEL-2004A is a 4-slot mainframe with a master control unit to hold 4 load modules, while PEL-2002A is a 2-slot mainframe with master control unit to hold 2 load modules. When the PEL-2004A is configured with 4 load modules rated at 350W each, the PEL-2000A series is able to sink up to 1.4kVA of power. | Agilent HP 60502B Electronic Load Module 0-60A, 3-60V, 300W | The Agilent HP 60501A is a 60 V, 30 A, 150W Electronic Load Module designed for use in a 6050A or 6051A Electronic Load Mainframe. The 60501A is ideal for the test and evaluation of dc power sources and power components and is well suited for applications in areas such as research and development, production, and incoming inspection. The 60501A module includes programming inputs that allow control of load current via an analog control voltage. The 60501A features full protection from over-current, over-voltage, overpower, over-temperature, and reverse polarity. Power connections are made via large high-current binding posts which permit rapid connections by hand and eliminate the traditional bolt/nut connections of the past. Internal or external load sensing is available. | The Keysight 60501B module along with the dc electronic load mainframe are ideal for the test and evaluation of dc power sources and power components and are well suited for applications in areas such as research and development, production, and incoming inspection. Each module includes programming inputs that allow control of load current via an analog control voltage. | ||||||||||||||||||||||||
Content | ||||||||||||||||||||||||||||||
Weight | 35 | 36 | 55 | 21 | 21 | 21 | ||||||||||||||||||||||||
Dimensions | 8 × 18 × 18 in | 10 × 24 × 12 in | 10 × 24 × 24 in | 8 × 10 × 26 in | 8 × 10 × 26 in | 8 × 10 × 26 in | ||||||||||||||||||||||||
Additional information |
|
|
|
|
|
|