In Stock

Rigol DSA815-TG 9kHz to 1.5GHz with Pre-Amplifier and Tracking Generator Spectrum Analyzer

Available for Quote

  • 2012-2014 top selling unit
  • 9 kHz to 1.5 GHz Frequency Range
  • Typical -135 dBm Displayed Average Noise Level (DANL)
  • -80 dBc/Hz @10 kHz offset Phase Noise
  • Total Amplitude Uncertainty <1.5 dB
  • 10 Hz Minimum Resolution Bandwidth (RBW) (As of 4/1/2017 – Previously 100 Hz)
  • Standard with Preamplifier and AM/FM Demodulation Function
  • 1.5 GHz Tracking Generator
  • 8 inch (800×480 pixels) high-definition display with clear,  vivid, and easy to use graphical interface
  • Complete connectivity with standard interfaces such as LAN, USB Host, USB Device and GPIB (optional)
  • Compact size, light weight 4.25kg (9.4lbs)
View List
SKU: N_Rigol DSA815-TG Category: Tag:

Quick Comparison

SettingsRigol DSA815-TG 9kHz to 1.5GHz with Pre-Amplifier and Tracking Generator Spectrum Analyzer removeGW Instek GAP-802 20dB Typical Preamplifier for GSP Series Spectrum Analyzer removeInstek GSP-9300B 9 kHz - 3 GHz Spectrum Analyzer with Built-in Preamp and Tracking Generator removeGKT-008 EMI Near Field Probe Set Test Lead / Probe Kit, ANT-04, ANT-05, ADP-002, GTL-303, PR-01, PR-02 removeInstek GLN-5040A Line Impedance Stabilization Networ - Line Impedance Stabilization Network [LISN] for GSP-9330 spectrum analyzer removeGW Instek GTL-401 DC Power Cord for GSP Series Spectrum Analyzer remove
Image
SKUN_Rigol DSA815-TGN_GW Instek GAP-802N_GW Instek GSP-9300BTGN_GW Instek GKT-008N_GW Instek GLN-5040AN_GW Instek GTL-401
Rating
PriceAvailable for QuoteAvailable for QuoteAvailable for QuoteAvailable for QuoteAvailable for QuoteAvailable for Quote
Stock
Availability
Add to cart

Add to Cart

Add to Cart

Add to Cart

Add to Cart

Add to Cart

Add to Cart

Description
  • 2012-2014 top selling unit
  • 9 kHz to 1.5 GHz Frequency Range
  • Typical -135 dBm Displayed Average Noise Level (DANL)
  • -80 dBc/Hz @10 kHz offset Phase Noise
  • Total Amplitude Uncertainty <1.5 dB
  • 10 Hz Minimum Resolution Bandwidth (RBW) (As of 4/1/2017 - Previously 100 Hz)
  • Standard with Preamplifier and AM/FM Demodulation Function
  • 1.5 GHz Tracking Generator
  • 8 inch (800×480 pixels) high-definition display with clear,  vivid, and easy to use graphical interface
  • Complete connectivity with standard interfaces such as LAN, USB Host, USB Device and GPIB (optional)
  • Compact size, light weight 4.25kg (9.4lbs)
Preamplifier [GSP-830 only]. 20dB Preamplifier Typical. Frequency Range 9kHz ~ 3GHzGSP-9300B is a 3GHz spectrum analyzer to meet basic RF measurement requirements. It provides the frequency stability of 0.025ppm; the aging rate of 1ppm/year; a built-in preamplifier; the base noise of -149dBm/Hz, and more than 20 measurement applications, including AM/FM modulation signal analysis, signal channel analysis, and CATV parameter test. While collocating with TG option, GSP-9300B can conduct frequency response or power linearity tests for components.Series Key Features
  • PR-01: AC voltage probe, 150kHz ~ 30MHz
  • PR-02: Electric field probe, 30MHz ~ 3GHz
  • ANT-04: Magnetic field probe, 30MHz ~ 3GHz
  • ANT-05: Magnetic field probe, 30MHz ~ 3GHz
  • ADP-002: Adaptor SMA(F) to N-type (M)
  • GTL-303: RF testing cable SMA(M) to SMA(M)
GKT-008 EMI Near Probe Set comprises of four probes, including the PR-01, PR-02, ANT-04, and ANT-05. The antenna factors of these four probes are built in the EMC Pretest function of the GSP-9330 spectrum analyzer. ANT-04 and ANT-05 are EMI magnetic field probes, which can maximally sustain 50Vdc. ANT-04 and ANT-05 magnetic field probes will collocate with ADB-008 DC block to avoid damaging spectrum analyzer and the RF input terminal of DUT receiver. PR-01 is an AC voltage probe, which can maximally sustain CAT II, 300VAC, PR-01 AC voltage probe will collocate with GPL-5010 transient limiter and BNC (M) to SMA (F) adapter to avoid damaging spectrum analyzer and the RF input terminal of DUT reciever. PR-02 is an EMI electric field probe, which can maximally sustain CAT I 50V DC. PR-02 electric field probe will collocate with ADB-008 DC block to avoid damaging spectrum analyzer and the RF input terminal of DUT receiver.
The GLN - 5040A Two Line V - Network is used for EMI testing. It provides stable impedance for the EUT terminals and the reference ground within the conducted emissions range. The GLN - 5040A also isolates the unwanted network signals from the power supply unit and only couples the disturbance voltage of the measured device to the receiver. The product's performance is in compliance with the standard requirements of CISPR16 - 1 - 2 for V - networks with a simulated impedance of 50? H + 5 ?) || 50 ? in the frequency range of 9kHz to 30MHz. It uses standard BNC output connector with 50 ? output impedance to match any measurement devices such as receivers and spectrum analyzers.
Content
Weight152103122
Dimensions16 × 8 × 8 in6 × 8 × 4 in14 × 8 × 10 in6 × 10 × 4 in23 × 18 × 11 in9 × 7 × 1 in
Additional information
Weight 15 lbs
Dimensions 16 × 8 × 8 in
Weight 2 lbs
Dimensions 6 × 8 × 4 in
Weight 10 lbs
Dimensions 14 × 8 × 10 in
Weight 3 lbs
Dimensions 6 × 10 × 4 in
Weight 12 lbs
Dimensions 23 × 18 × 11 in
Weight 2 lbs