In Stock

GW Instek GPM-8310 Digital AC Power Meter with LAN/GPIB up to 100KHz

Available for Quote

Key Features

 5” TFT LCD
 DC, 0.1Hz ~ 100kHz voltage/current test bandwidth
 Two numerical display modes
 General mode: displays 2 main test items + 8 secondary test items
 Simple mode: displays the test values of 4 main test items
 Waveform display: V (voltage), I (current), P (power)
 The current/voltage can be measured to a deformed wave with CF of 3,
and the half-range CF can reach 6 or 6A
 50th order of harmonic measurement and analysis (value and bar
graph)
 Integration function supports automatic level-changing
 External current sensor input terminals (EXT1/EXT2)
 Standard interfaces: RS-232C, USB device/ host, LAN, GPIB
 Optional interface: Digital I/O (DA4) (must be installed before leaving the
factory)
 Optional accessory: GPM-001

View List
SKU: N_GW Instek GPM-8310 Category: Tag:

Quick Comparison

SettingsGW Instek GPM-8310 Digital AC Power Meter with LAN/GPIB up to 100KHz removeInstek PLR 36-10 DC Power Supply, 36V, 10A, 360W Low Noise removeInstek PSU-03C Cable for 4 units in parallel operation removeInstek PSU-03B Bus Bar for 4 units in parallel operation removeGW Instek GPD-2303S 180W Dual-Output Programmable Linear DC Power Supply, 30V DC, 3 Amp removeGW Instek PLR 20-36 DC Power Supply, 20V, 36A, 720W Low Noise remove
Image
SKUN_GW Instek GPM-8310N_GW Instek PLR 36-10N_GW Instek PSU-03CN_GW Instek PSU-03BN_GW Instek GPD-2303SN_GW Instek PLR 20-36
Rating
PriceAvailable for QuoteAvailable for QuoteAvailable for QuoteAvailable for QuoteAvailable for QuoteAvailable for Quote
Stock
Availability
Add to cart

Add to Cart

Add to Cart

Add to Cart

Add to Cart

Add to Cart

Add to Cart

DescriptionKey Features  5” TFT LCD  DC, 0.1Hz ~ 100kHz voltage/current test bandwidth  Two numerical display modes  General mode: displays 2 main test items + 8 secondary test items  Simple mode: displays the test values of 4 main test items  Waveform display: V (voltage), I (current), P (power)  The current/voltage can be measured to a deformed wave with CF of 3, and the half-range CF can reach 6 or 6A  50th order of harmonic measurement and analysis (value and bar graph)  Integration function supports automatic level-changing  External current sensor input terminals (EXT1/EXT2)  Standard interfaces: RS-232C, USB device/ host, LAN, GPIB  Optional interface: Digital I/O (DA4) (must be installed before leaving the factory)  Optional accessory: GPM-001

Hybrid Linear, Low noise, 0-36V/0-10A, 360W

  • Output Voltage Rating: 36V
  • Output Power: 360W
  • Low Ripple and Noise (0.5mVrms/ 10mArms)
  • Fast transition recovery time (100us)
  • Maximum 2 units in series connections or 3 units in parallel connections
  • Select the setting digits for voltage and current (coarse/ fine volume control)
  • Panel Lock Function
  • 3 set of preset function
  • Output off timer function (Range: 1min to 1000hours & 59mins)
  • CC priority function (prevent overshoot & inrush current)
  • Sequence function of PC editing (Max.: 1000 steps/ Min. step period: 50ms)
  • Protection: OVP, UVP, OCP, remote sensing (Terminal open)
  • External Analog Control Function
  • PC Remote Interface (Standard): RS-232; (Optional): GPIB / USB / LAN
  • CE Compliance
180W, 2ch Output DC Programmable Power Supply 4 Outputs for GPD-4303S High Resolution Display 1mV / 1mA (GPD-X303S) CH1/CH2 Output: 30V / 3A CH3 Selectable Output: 5V/3A ; 5.001V-10V /1A (GPD-4303S) CH4 Output: 5V / 1A (GPD-4303S) Auto Series / Parallel Tracking Mode Digital Panel ControlRotary Encoder Switch and Rubber Key with Backlight 4 Sets SAVE / RECALL panel setting User Friendly Operation, Coarse and Fine Voltage Control Warning Buzzer Output On / Off Switch USB Device for Remote Control (Baud Rate 115200 bps Maximum) Free downloadable PC software Smart Cooling Fan with Low Noise Safety Design: Reverse Polarity, Overload Protection

Hybrid Linear, Low noise, 0-20V/0-36A, 720W

  • Output Voltage Rating: 20V
  • Output Power: 720W
  • Low Ripple and Noise (0.5mVrms/ 10mArms)
  • Fast transition recovery time (100us)
  • Maximum 2 units in series connections or 3 units in parallel connections
  • Select the setting digits for voltage and current (coarse/ fine volume control)
  • Panel Lock Function
  • 3 set of preset function
  • Output off timer function (Range: 1min to 1000hours & 59mins)
  • CC priority function (prevent overshoot & inrush current)
  • Sequence function of PC editing (Max.: 1000 steps/ Min. step period: 50ms)
  • Protection: OVP, UVP, OCP, remote sensing (Terminal open)
  • External Analog Control Function
  • PC Remote Interface (Standard): RS-232; (Optional): GPIB / USB / LAN
  • CE Compliance
Content
Weight2215221515
Dimensions12 × 14 × 6 in18 × 12 × 10 in4 × 6 × 2 in4 × 6 × 2 in18 × 12 × 10 in18 × 12 × 10 in
Additional information
Weight 22 lbs
Dimensions 12 × 14 × 6 in
Weight 15 lbs
Dimensions 18 × 12 × 10 in
Weight 2 lbs
Dimensions 4 × 6 × 2 in
Weight 2 lbs
Dimensions 4 × 6 × 2 in
Weight 15 lbs
Dimensions 18 × 12 × 10 in
Weight 15 lbs
Dimensions 18 × 12 × 10 in