In Stock

Instek LCR-6002 10Hz ~ 2kHz High Precision LCR Meter

Available for Quote

GW Instek introduces the brand new high precision LCR meter – LCR-6000 series, which, with five models, has a test frequency range extending from 2kHz/20kHz/100kHz/200kHz/300kHz (maximum) and with 0.05% basic accuracy. The compact size design, 2U height and 1/2 rack, is one of the practical features of the series which is the optimum space saver suitable for either bench top or system rack. The compacted LCR-6000 series with abundant features is absolutely the excellent tool for R&D, production test, IQC, etc. on implementing each test stages for passive components.

View List
SKU: N_GW Instek LCR-6002 Category: Tag:

Quick Comparison

SettingsInstek LCR-6002 10Hz ~ 2kHz High Precision LCR Meter removeGW Instek GPD-3303D 195W Triple-Output Programmable Linear DC Power Supply 30V , 3 A, 100mV, 10-milliamp Resolution removeInstek GPS-1850D 90W Single-Output Linear DC Power Supply with Digital LED screen, 18V DC, 5 Amp removeGW Instek GPE-4323 GPE-X323 Multi-Output DC Power Supply, 4 Channel, 212W, 0-32 VDC, 0-3A, 0-5V/1A, 0-15V/1A removeGW Instek PLR 20-18 DC Power Supply, 20V, 18A, 360W Low Noise removeGW Instek GPR-3510HD Single Output Linear DC Power Supply with LED Display, 10 Output Amps, 35 Output Volts, 350 Output Watts remove
Image
SKUN_GW Instek LCR-6002N_GW Instek GPC-3030DN_GW Instek GPS-1850DN_GW Instek GPE-4323N_GW Instek PLR 20-18N_GW Instek GPR-3510HD
Rating
PriceAvailable for QuoteAvailable for QuoteAvailable for QuoteAvailable for QuoteAvailable for QuoteAvailable for Quote
Stock
Availability
Add to cart

Add to Cart

Add to Cart

Add to Cart

Add to Cart

Add to Cart

Add to Cart

DescriptionGW Instek introduces the brand new high precision LCR meter - LCR-6000 series, which, with five models, has a test frequency range extending from 2kHz/20kHz/100kHz/200kHz/300kHz (maximum) and with 0.05% basic accuracy. The compact size design, 2U height and 1/2 rack, is one of the practical features of the series which is the optimum space saver suitable for either bench top or system rack. The compacted LCR-6000 series with abundant features is absolutely the excellent tool for R&D, production test, IQC, etc. on implementing each test stages for passive components.0-30Vx2,0-3Ax2; 2.5V/3.3V/5V,3A, USB; 2 3/4 digit Three Independent Output : 30V/3A x 2, 2.5V/3.3V/5V/3A x 1 4 LED Display Sets : 3 Digits After Decimal Point Minimum Resolution : 100mV/10mA Digital Panel Control (Rotary Encoder Switch, Rubber Key With Indicator) Key-Lock User-Friendly Operation, Coarse/Fine Voltage Control 4 Panel Settings Save/Recall (Plus Factory Settings Recall) Output ON/OFF Tracking Series and Parallel Mode USB Device for Remote Control (Baud Rate 115200 bps Maximum) Free downloadable PC software Smart Cooling Fan Achieving Low Noise Warning Buzzer Light-Weight and Compact Design90W DC Linear Power Supply 0-18V, 0-5A DIGITAL 0-5A DIGITAL Light and Compact Design 0.01% High Regulation Constant Voltage and Constant Current Operation Remote Control for External Programmability Internal Select for Continuous or Dynamic Load Low Ripple and Noise Overload and Reverse Polarity Protection Series or Parallel Operation212W 4 Channel DC Power Supply GPE-4323 4 Channels, 212W Linear DC Power Supply 4 Independent Isolated Output 10mv min resolution 1ma min resolution 4.3 Inch LCD Display Setting & Read back Resolution 10mA / 1mA Output ON/OFF Analog Control (Remote I/O) for Output ON / OFF Set View function for checking an original V / I setting during output on Key Lock Function Tracking series and parallel operation Smart cooling fan achieving low noise Optional European Jack Type Terminal

Hybrid Linear, Low noise, 0-20V/0-18A, 360W

  • Output Voltage Rating: 20V
  • Output Power: 360W
  • Low Ripple and Noise (0.5mVrms/ 10mArms)
  • Fast transition recovery time (100us)
  • Maximum 2 units in series connections or 3 units in parallel connections
  • Select the setting digits for voltage and current (coarse/ fine volume control)
  • Panel Lock Function
  • 3 set of preset function
  • Output off timer function (Range: 1min to 1000hours & 59mins)
  • CC priority function (prevent overshoot & inrush current)
  • Sequence function of PC editing (Max.: 1000 steps/ Min. step period: 50ms)
  • Protection: OVP, UVP, OCP, remote sensing (Terminal open)
  • External Analog Control Function
  • PC Remote Interface (Standard): RS-232; (Optional): GPIB / USB / LAN
  • CE Compliance
350W DC Linear Power Supply 0-35V, 0-10A 0-35V, 0-10A 0.01% High Regulation Constant Voltage and Constant Current Operation Internal Select for Continuous or Dynamic Load Low Ripple and Noise Overload and Reverse Polarity Protection 3 1/2 Digit 0.5" LED Display
Content
Weight101515151515
Dimensions16 × 10 × 8 in18 × 12 × 10 in18 × 12 × 10 in18 × 12 × 10 in18 × 12 × 10 in18 × 12 × 10 in
Additional information
Weight 10 lbs
Dimensions 16 × 10 × 8 in
Weight 15 lbs
Dimensions 18 × 12 × 10 in
Weight 15 lbs
Dimensions 18 × 12 × 10 in
Weight 15 lbs
Dimensions 18 × 12 × 10 in
Weight 15 lbs
Dimensions 18 × 12 × 10 in
Weight 15 lbs
Dimensions 18 × 12 × 10 in