Description | GW Instek introduces the brand new high precision LCR meter - LCR-6000 series, which, with five models, has a test frequency range extending from 2kHz/20kHz/100kHz/200kHz/300kHz (maximum) and with 0.05% basic accuracy. The compact size design, 2U height and 1/2 rack, is one of the practical features of the series which is the optimum space saver suitable for either bench top or system rack. The compacted LCR-6000 series with abundant features is absolutely the excellent tool for R&D, production test, IQC, etc. on implementing each test stages for passive components. | Hybrid Linear, Low noise, 0-20V/0-18A, 360W
- Output Voltage Rating: 20V
- Output Power: 360W
- Low Ripple and Noise (0.5mVrms/ 10mArms)
- Fast transition recovery time (100us)
- Maximum 2 units in series connections or 3 units in parallel connections
- Select the setting digits for voltage and current (coarse/ fine volume control)
- Panel Lock Function
- 3 set of preset function
- Output off timer function (Range: 1min to 1000hours & 59mins)
- CC priority function (prevent overshoot & inrush current)
- Sequence function of PC editing (Max.: 1000 steps/ Min. step period: 50ms)
- Protection: OVP, UVP, OCP, remote sensing (Terminal open)
- External Analog Control Function
- PC Remote Interface (Standard): RS-232; (Optional): GPIB / USB / LAN
- CE Compliance
| | 240W DC Linear Power Supply 0-8V, 0-30A
0-8V, 0-30A
0.01% High Regulation
Constant Voltage and Constant Current Operation
Internal Select for Continuous or Dynamic Load
Low Ripple and Noise
Overload and Reverse Polarity Protection
3 1/2 Digit 0.5" LED Display | 300W DC Linear Power Supply 0-300V, 0-1A
0-300V, 0-1A
0.01% High Regulation
Constant Voltage and Constant Current Operation
Internal Select for Continuous or Dynamic Load
Low Ripple and Noise
Overload and Reverse Polarity Protection
3 1/2 Digit 0.5" LED Display | Hybrid Linear, Low noise, 0-20V/0-36A, 720W
- Output Voltage Rating: 20V
- Output Power: 720W
- Low Ripple and Noise (0.5mVrms/ 10mArms)
- Fast transition recovery time (100us)
- Maximum 2 units in series connections or 3 units in parallel connections
- Select the setting digits for voltage and current (coarse/ fine volume control)
- Panel Lock Function
- 3 set of preset function
- Output off timer function (Range: 1min to 1000hours & 59mins)
- CC priority function (prevent overshoot & inrush current)
- Sequence function of PC editing (Max.: 1000 steps/ Min. step period: 50ms)
- Protection: OVP, UVP, OCP, remote sensing (Terminal open)
- External Analog Control Function
- PC Remote Interface (Standard): RS-232; (Optional): GPIB / USB / LAN
- CE Compliance
|
Additional information |
Weight |
10 lbs |
Dimensions |
16 × 10 × 8 in |
|
Weight |
15 lbs |
Dimensions |
18 × 12 × 10 in |
|
Weight |
2 lbs |
Dimensions |
4 × 6 × 2 in |
|
Weight |
15 lbs |
Dimensions |
18 × 12 × 10 in |
|
Weight |
15 lbs |
Dimensions |
18 × 12 × 10 in |
|
Weight |
15 lbs |
Dimensions |
18 × 12 × 10 in |
|