Description | Test Fixture 45V DC Bias Voltage Box for LCR-6000 Series | Hybrid Linear, Low noise, 0-36V/0-10A, 360W
- Output Voltage Rating: 36V
- Output Power: 360W
- Low Ripple and Noise (0.5mVrms/ 10mArms)
- Fast transition recovery time (100us)
- Maximum 2 units in series connections or 3 units in parallel connections
- Select the setting digits for voltage and current (coarse/ fine volume control)
- Panel Lock Function
- 3 set of preset function
- Output off timer function (Range: 1min to 1000hours & 59mins)
- CC priority function (prevent overshoot & inrush current)
- Sequence function of PC editing (Max.: 1000 steps/ Min. step period: 50ms)
- Protection: OVP, UVP, OCP, remote sensing (Terminal open)
- External Analog Control Function
- PC Remote Interface (Standard): RS-232; (Optional): GPIB / USB / LAN
- CE Compliance
| 217W 3 Channel DC Power Supply
GPE-3323 3 Channels, 217W Linear DC Power Supply
3 Independent Isolated Output
10mv min resolution 1ma min resolution
4.3 Inch LCD Display
Setting & Read back Resolution 10mA / 1mA
Output ON/OFF
Analog Control (Remote I/O) for Output ON / OFF
Set View function for checking an original V / I setting during output on
Key Lock Function
Tracking series and parallel operation
Smart cooling fan achieving low noise
Optional European Jack Type Terminal | | SFG-1000 Series, an economic function generator with high accuracy and high stability output, is designed based on the DDS (Direct Digital Synthesis) technology embedded in a large scale FPGA. The frequency range of 3MHz and the output waveform selection as Sine, Square, Triangle and TTL of SFG-1000 Series adequately provide the fundamental features to ensure high confidence for the test results. The DDS technology at an affordable price gives a high-value solution to the users who need a signal source for accurate but unsophisticated measurement applications. | Hybrid Linear, Low noise, 0-20V/0-18A, 360W
- Output Voltage Rating: 20V
- Output Power: 360W
- Low Ripple and Noise (0.5mVrms/ 10mArms)
- Fast transition recovery time (100us)
- Maximum 2 units in series connections or 3 units in parallel connections
- Select the setting digits for voltage and current (coarse/ fine volume control)
- Panel Lock Function
- 3 set of preset function
- Output off timer function (Range: 1min to 1000hours & 59mins)
- CC priority function (prevent overshoot & inrush current)
- Sequence function of PC editing (Max.: 1000 steps/ Min. step period: 50ms)
- Protection: OVP, UVP, OCP, remote sensing (Terminal open)
- External Analog Control Function
- PC Remote Interface (Standard): RS-232; (Optional): GPIB / USB / LAN
- CE Compliance
|
Additional information |
Weight |
2 lbs |
Dimensions |
8 × 10 × 6 in |
|
Weight |
15 lbs |
Dimensions |
18 × 12 × 10 in |
|
Weight |
15 lbs |
Dimensions |
18 × 12 × 10 in |
|
Weight |
2 lbs |
Dimensions |
4 × 6 × 2 in |
|
Weight |
6 lbs |
Dimensions |
15 × 12 × 6 in |
|
Weight |
15 lbs |
Dimensions |
18 × 12 × 10 in |
|