In Stock

Chroma 63640-80-80 DC Load Module, 400W, 80V, 80A

Available for Quote

The Chroma 63640-80-80 DC load module provides three operating current ranges and a built-in 16-bit, precision A/D converter, achieving 0.025%+0.01%F.S., 0.05%+0.05%F.S. and 0.1%+0.1%F.S. accuracy for voltage, current and power measurement respectively. Real time measurement of voltage and current are integrated into each Chroma 63640-80-80 load module. The Chroma 63640-80-80 offers high speed, programmable dynamic loading, sweep simulation and control capability never before achieved. When the need is for increased power, paralleling two or more loads can be done to achieve the desired load current. Using several loads in parallel to emulate a single load dramatically simplifies operation and allows them to be used for both multiple output power supplies and larger single output supplies.

1 in stock

View List
SKU: Chroma 63640-80-80 Category: Tag:

Quick Comparison

SettingsChroma 63640-80-80 DC Load Module, 400W, 80V, 80A removeGW Instek PEL-2020 Programmable DC Electronic Load Dual Channel Module, 1~80V, 20A, 100W removeGW INSTEK PEL-3211 DC LOAD, PROGRAMMABLE, 420A, 1.5-150V, 2.1KW removeGW Instek PEL-2030 Programmable DC Electronic Load Dual Channel Module, (1~80V, 5A, 30W) + (1~80V, 40A, 250W) removeGW Instek PEL-2004A 4-Slot Programmable DC Electronic Load Mainframe removeAgilent 60504B Electronic Load Module 600 Watt, 60V, 60A remove
Image
SKUChroma 63640-80-80N_GW Instek PEL-2020AN_GW Instek PEL-3211N_GW Instek PEL-2030AN_GW Instek PEL-2004AAgilent 60504B
Rating
PriceAvailable for QuoteAvailable for QuoteAvailable for QuoteAvailable for QuoteAvailable for QuoteAvailable for Quote
Stock

1 in stock

1 in stock

Availability1 in stock1 in stock
Add to cart

Add to Cart

Add to Cart

Add to Cart

Add to Cart

Add to Cart

Add to Cart

Description The Chroma 63640-80-80 DC load module provides three operating current ranges and a built-in 16-bit, precision A/D converter, achieving 0.025%+0.01%F.S., 0.05%+0.05%F.S. and 0.1%+0.1%F.S. accuracy for voltage, current and power measurement respectively. Real time measurement of voltage and current are integrated into each Chroma 63640-80-80 load module. The Chroma 63640-80-80 offers high speed, programmable dynamic loading, sweep simulation and control capability never before achieved. When the need is for increased power, paralleling two or more loads can be done to achieve the desired load current. Using several loads in parallel to emulate a single load dramatically simplifies operation and allows them to be used for both multiple output power supplies and larger single output supplies.The PEL-2000A Series includes two types of mainframes and 4 types of load modules to accommodate users' requirements in a flexible manner. Any load module combination can be used with a mainframe to tailor a test system based on the number of channels, and the maximum load power, voltage and current of each channel. Multiple loads can be connected in parallel to provide a higher-power load to test higher power supply outputs. This flexibility significantly reduces the investment needed for future projects that have different power requirements. The PEL-2004A is a 4-slot mainframe with a master control unit to hold 4 load modules, while PEL-2002A is a 2-slot mainframe with master control unit to hold 2 load modules. When the PEL-2004A is configured with 4 load modules rated at 350W each, the PEL-2000A series is able to sink up to 1.4kVA of power.2100 W Booster Unit [for use with PEL-3111 only]The PEL-2000A Series includes two types of mainframes and 4 types of load modules to accommodate users' requirements in a flexible manner. Any load module combination can be used with a mainframe to tailor a test system based on the number of channels, and the maximum load power, voltage and current of each channel. Multiple loads can be connected in parallel to provide a higher-power load to test higher power supply outputs. This flexibility significantly reduces the investment needed for future projects that have different power requirements. The PEL-2004A is a 4-slot mainframe with a master control unit to hold 4 load modules, while PEL-2002A is a 2-slot mainframe with master control unit to hold 2 load modules. When the PEL-2004A is configured with 4 load modules rated at 350W each, the PEL-2000A series is able to sink up to 1.4kVA of power.The PEL-2000A Series includes two types of mainframes and 4 types of load modules to accommodate users' requirements in a flexible manner. Any load module combination can be used with a mainframe to tailor a test system based on the number of channels, and the maximum load power, voltage and current of each channel. Multiple loads can be connected in parallel to provide a higher-power load to test higher power supply outputs. This flexibility significantly reduces the investment needed for future projects that have different power requirements. The PEL-2004A is a 4-slot mainframe with a master control unit to hold 4 load modules, while PEL-2002A is a 2-slot mainframe with master control unit to hold 2 load modules. When the PEL-2004A is configured with 4 load modules rated at 350W each, the PEL-2000A series is able to sink up to 1.4kVA of power.
Content
Weight353616365532
Dimensions8 × 18 × 18 in10 × 24 × 12 in10 × 24 × 12 in10 × 24 × 12 in10 × 24 × 24 in8 × 10 × 26 in
Additional information
Weight 35 lbs
Dimensions 8 × 18 × 18 in
Weight 36 lbs
Dimensions 10 × 24 × 12 in
Weight 16 lbs
Dimensions 10 × 24 × 12 in
Weight 36 lbs
Dimensions 10 × 24 × 12 in
Weight 55 lbs
Dimensions 10 × 24 × 24 in
Weight 32 lbs
Dimensions 8 × 10 × 26 in