The 63200A series high power DC electronic loads are designed for testing a wide range of power conversion products including AC/DC and server power supplies, DC/DC converters, EV batteries, automotive charging stations, and other power electronics components. These units can be synchronously paralleled up to 240kW and dynamically synchronized for generating complex multi-channel transient profiles. The 300% peak overpower capability provides extra headroom for fault condition simulations in automotive batteries, fuel cells, and more.

1 in stock

View List
SKU: Chroma 63204 Category: Tag:

Quick Comparison

SettingsChroma 63204-150-400 High Power DC Electronic Load 150V / 400A / 4kW (4U) removeAgilent 6063B 250 Watt DC Electronic Load, 3V-240V, 10A, 250W removeAgilent 60504A DC Electronic Load 500W, 60V, 120A removeAgilent 6060B Electronic Load, 3 to 60 V, 0 to 60 A, 300W removeGW Instek PEL-3111 DC Electronic Load, 1050 W, 1.5V~150V, 210A removeGW Instek PEL-2004A 4-Slot Programmable DC Electronic Load Mainframe remove
Image
SKUChroma 63204Agilent 6063BAgilent 60504AAgilent 6060BN_GW Instek PEL-3111N_GW Instek PEL-2004A
Rating
PriceAvailable for QuoteAvailable for QuoteAvailable for QuoteAvailable for QuoteAvailable for QuoteAvailable for Quote
Stock

1 in stock

1 in stock

1 in stock

1 in stock

Availability1 in stock1 in stock1 in stock1 in stock
Add to cart

Add to Cart

Add to Cart

Add to Cart

Add to Cart

Add to Cart

Add to Cart

DescriptionThe 63200A series high power DC electronic loads are designed for testing a wide range of power conversion products including AC/DC and server power supplies, DC/DC converters, EV batteries, automotive charging stations, and other power electronics components. These units can be synchronously paralleled up to 240kW and dynamically synchronized for generating complex multi-channel transient profiles. The 300% peak overpower capability provides extra headroom for fault condition simulations in automotive batteries, fuel cells, and more.The Keysight 6063B is a 250 W, single output electronic load, ideal for evaluation of DC power sources and power components in bench applications. The 6063B has built-in measurement functions that make it convenient for testing single output applications in areas such as research and development, production, and incoming inspection.The Agilent 6060B is a 300 W, single output electronic load, ideal for evaluation of DC power sources and power components in bench applications. The 6060B has built-in measurement functions that make it convenient for testing single output applications in areas such as research and development, production, and incoming inspection.The PEL-3000 Series, a single-channel, programmable D.C. electronic load with 0.01 mA current resolution and 16A/ z s current Slew Rate, is very ideal for testing server power supply and SPS (Switching Power Supply) for commercial and industrial computers. For a heavy-duty device like cloud ecosystem running 24-hour nonstop operations, a stable and high-power power supply, ranging from 350W to 1500W, is required to maintain the normal operation of server, Hub, and the equipment of data storage and internet communications. Owing to the increasing demand of data transmission and large scale data storage of telecommunications systems, the infrastructure of internet communications is in the pace of rapid expansion. This has greatly boosted the market demand of telecommunications equipment powered by power supply of 2000W and above. The flexible power combination of PEL-3000 meets the test requirements of present high- power power supply. With respect to battery testing applications such as rechargeable battery for electrical tools, battery module and automobile battery, PEL-3000 has three stand-alone models to offer including 175W, 350W, 1050W and 1050W. By connecting Booster 2100W units with master units, the maximum load capacity of the whole system can reach 9,450W Hence, the PEL-3000 Series fulfills various power testing requirements including medium to low power or high-power power supply.The PEL-2000A Series includes two types of mainframes and 4 types of load modules to accommodate users' requirements in a flexible manner. Any load module combination can be used with a mainframe to tailor a test system based on the number of channels, and the maximum load power, voltage and current of each channel. Multiple loads can be connected in parallel to provide a higher-power load to test higher power supply outputs. This flexibility significantly reduces the investment needed for future projects that have different power requirements. The PEL-2004A is a 4-slot mainframe with a master control unit to hold 4 load modules, while PEL-2002A is a 2-slot mainframe with master control unit to hold 2 load modules. When the PEL-2004A is configured with 4 load modules rated at 350W each, the PEL-2000A series is able to sink up to 1.4kVA of power.
Content
Weight353232323655
Dimensions8 × 18 × 18 in26 × 26 × 12 in8 × 10 × 26 in26 × 26 × 12 in10 × 24 × 24 in10 × 24 × 24 in
Additional information
Weight 35 lbs
Dimensions 8 × 18 × 18 in
Weight 32 lbs
Dimensions 26 × 26 × 12 in
Weight 32 lbs
Dimensions 8 × 10 × 26 in
Weight 32 lbs
Dimensions 26 × 26 × 12 in
Weight 36 lbs
Dimensions 10 × 24 × 24 in
Weight 55 lbs
Dimensions 10 × 24 × 24 in