Out of Stock

Chroma 63102A Electronic Load Module 100W, 20A, 60V Dual Channel

Available for Quote

20 A, 80 V, or 100 W max. – Dual Channel. Compatibility between 6310 and 6310A. Synchronization with multiple loads

Out of stock

SKU: Chroma 63102A Category: Tag:

Quick Comparison

SettingsChroma 63102A Electronic Load Module 100W, 20A, 60V Dual Channel removeGW INSTEK PEL-3041 DC LOAD, PROGRAMMABLE, 70A, 1.5-150V, 350W removeGW Instek PEL-2002A 2-Slot Programmable DC Electronic Load Mainframe removeGW Instek PEL-2004A 4-Slot Programmable DC Electronic Load Mainframe removeAgilent 60504B Electronic Load Module 600 Watt, 60V, 60A removeGW Instek PEL-2030 Programmable DC Electronic Load Dual Channel Module, (1~80V, 5A, 30W) + (1~80V, 40A, 250W) remove
Image
SKUChroma 63102A N_GW Instek PEL-3041N-GW Instek PEL-2002AN_GW Instek PEL-2004AAgilent 60504BN_GW Instek PEL-2030A
Rating
PriceAvailable for QuoteAvailable for QuoteAvailable for QuoteAvailable for QuoteAvailable for QuoteAvailable for Quote
Stock

Out of stock

1 in stock

AvailabilityOut of stock1 in stock
Add to cart

Add to Cart

Add to Cart

Add to Cart

Add to Cart

Add to Cart

Add to Cart

Description20 A, 80 V, or 100 W max. - Dual Channel. Compatibility between 6310 and 6310A. Synchronization with multiple loads The PEL-3000 Series, a single-channel, programmable D.C. electronic load with 0.01 mA current resolution and 16A/ z s current Slew Rate, is very ideal for testing server power supply and SPS (Switching Power Supply) for commercial and industrial computers. For a heavy-duty device like cloud ecosystem running 24-hour nonstop operations, a stable and high-power power supply, ranging from 350W to 1500W, is required to maintain the normal operation of server, Hub, and the equipment of data storage and internet communications. Owing to the increasing demand of data transmission and large scale data storage of telecommunications systems, the infrastructure of internet communications is in the pace of rapid expansion. This has greatly boosted the market demand of telecommunications equipment powered by power supply of 2000W and above. The flexible power combination of PEL-3000 meets the test requirements of present high- power power supply. With respect to battery testing applications such as rechargeable battery for electrical tools, battery module and automobile battery, PEL-3000 has three stand-alone models to offer including 175W, 350W, 1050W and 1050W. By connecting Booster 2100W units with master units, the maximum load capacity of the whole system can reach 9,450W Hence, the PEL-3000 Series fulfills various power testing requirements including medium to low power or high-power power supply.The PEL-2000A Series includes two types of mainframes and 4 types of load modules to accommodate users' requirements in a flexible manner. Any load module combination can be used with a mainframe to tailor a test system based on the number of channels, and the maximum load power, voltage and current of each channel. Multiple loads can be connected in parallel to provide a higher-power load to test higher power supply outputs. This flexibility significantly reduces the investment needed for future projects that have different power requirements. The PEL-2004A is a 4-slot mainframe with a master control unit to hold 4 load modules, while PEL-2002A is a 2-slot mainframe with master control unit to hold 2 load modules. When the PEL-2004A is configured with 4 load modules rated at 350W each, the PEL-2000A series is able to sink up to 1.4kVA of power.The PEL-2000A Series includes two types of mainframes and 4 types of load modules to accommodate users' requirements in a flexible manner. Any load module combination can be used with a mainframe to tailor a test system based on the number of channels, and the maximum load power, voltage and current of each channel. Multiple loads can be connected in parallel to provide a higher-power load to test higher power supply outputs. This flexibility significantly reduces the investment needed for future projects that have different power requirements. The PEL-2004A is a 4-slot mainframe with a master control unit to hold 4 load modules, while PEL-2002A is a 2-slot mainframe with master control unit to hold 2 load modules. When the PEL-2004A is configured with 4 load modules rated at 350W each, the PEL-2000A series is able to sink up to 1.4kVA of power.The PEL-2000A Series includes two types of mainframes and 4 types of load modules to accommodate users' requirements in a flexible manner. Any load module combination can be used with a mainframe to tailor a test system based on the number of channels, and the maximum load power, voltage and current of each channel. Multiple loads can be connected in parallel to provide a higher-power load to test higher power supply outputs. This flexibility significantly reduces the investment needed for future projects that have different power requirements. The PEL-2004A is a 4-slot mainframe with a master control unit to hold 4 load modules, while PEL-2002A is a 2-slot mainframe with master control unit to hold 2 load modules. When the PEL-2004A is configured with 4 load modules rated at 350W each, the PEL-2000A series is able to sink up to 1.4kVA of power.
Content
Weight351636553236
Dimensions8 × 18 × 18 in10 × 24 × 12 in10 × 24 × 12 in10 × 24 × 24 in8 × 10 × 26 in10 × 24 × 12 in
Additional information
Weight 35 lbs
Dimensions 8 × 18 × 18 in
Weight 16 lbs
Dimensions 10 × 24 × 12 in
Weight 36 lbs
Dimensions 10 × 24 × 12 in
Weight 55 lbs
Dimensions 10 × 24 × 24 in
Weight 32 lbs
Dimensions 8 × 10 × 26 in
Weight 36 lbs
Dimensions 10 × 24 × 12 in