GDS-3000 Series Digital Storage Oscilloscopes
Features
- 500/350/250/150MHz with 2/4 Channels
- 5GSa/s RT or 100GSa/s ET Sampling Rate
- Independent Memory for Each Channel
- VPO Technology
- Large 8-inch 800×600 Display
- Split Screen Function
- 3 Built-in Impedances (50Ω/75Ω/1MΩ)
- Power Analysis Software (Optional)
- Serial Bus Analysis Software for I2C, SPI and UART (Optional)
A Hi-tech DSO Platform
The GDS-3000 Series is a platform of 4-input channels, 500MHz bandwidth, 5GSa/s sampling rate, and VPO waveform display. The split screen feature has been designed to meet the requirements of multi-window & multi-signal tests in the research and the manufacturing fields. The optional power analysis software and the optional serial bus analysis software are available to facilitate the engineer’s tasks in testing and manufacturing of the associated products.
The differential probe, GDP-025, GDP-050 & GDP-100, and current probes, GCP-020, GCP-100 and GCP-530 & GCP-1030, are coming along with the GDS-3000 Series to provide total solutions for a wide variety of applications in the industry, service and education market sectors. The GDS-3000 Series, a high-tech platform carrying thoughtful features, brings very high customer value to both general purpose market and professional market.
Manufacturer Specs
Model | GDS-3152 | GDS-3154 | GDS-3252 | GDS-3254 | GDS-3352 | GDS-3354 | GDS-3502 | GDS-3504 |
Vertical | ||||||||
Input Channels | 2Ch+EXT | 4Ch+EXT | 2Ch+EXT | 4Ch+EXT | 2Ch+EXT | 4Ch+EXT | 2Ch+EXT | 4Ch+EXT |
Bandwidth | DC~150MHz(-3dB) | DC~250MHz(-3dB) | DC~350MHz(-3dB) | DC~500MHz(-3dB) | ||||
Rise Time | 2.3ns | 1.4ns | 1ns | 700ps | ||||
Vertical Resolution | 8 bits | |||||||
Vertical Resolution@ 1MΩ | 2mV~5V/div | |||||||
Vertical Resolution@ 50/75Ω | 2mV~1V/div | |||||||
Input Coupling | AC, DC, GND | |||||||
Input Impedance | 1MΩ// 16pF | |||||||
DC Gain Accuracy | +(3% X |reading| + 0.1div+ 1mV) | |||||||
Polarity | Normal and inverted | |||||||
Maximum Input Impedance @1MΩ | 300V (DC+AC peak), CAT I | |||||||
Maximum Input Impedance @50/75Ω | 5 Vrms ,CAT I | |||||||
Offset Position Range | 2mV/div ~ 100mV/div: 0.5V 200mV/div ~ 5V/div: 25V | |||||||
Bandwidth Limit | 20MHz (-3dB) | 100MHz (-3dB) | 200MHz (-3dB) | 20MHz/ 100MHz/ 200MHz/ 350MHz (-3dB) | ||||
Waveform Signal Processing | Addition, Subtraction, multiplication, division, FFT, FFTrms | |||||||
Trigger | ||||||||
Source | Dual channel: CH1, CH2, Line, Ext ; 4 channel: CH1, CH2, CH3, CH4, Line, Ext | |||||||
Trigger Mode | Auto (Auto (supports Roll Mode for 100 ms/div and slower), Normal, Single | |||||||
Trigger Type | Edge, Pulse Width, Video, Runt, Rise & Fall, Alternative, Event-Delay (1~65,535) events, Time-Delay(10nS~10S), I2C, SPI, UART | |||||||
TriggerHold-off Range | 10ns~10s | |||||||
Coupling | AC, DC, LF rej, HF rej, Noise rej | |||||||
Sensitivity | DC~50MHz approx. 1div or 1.0mV 50MHz~150MHz approx. 1.5div or 15mV 150MHz~350MHz approx. 2div or 20mV | |||||||
EXT Trigger | ||||||||
Range | 15V | |||||||
Sensitivity | DC~150MHz pprox.100mV 150MHz~250MHz approx. 150mV 250MHz~350MHz approx. 150mV | |||||||
Input Impedance | 1MΩ3%, ~16pF | |||||||
Horizontal | ||||||||
Range | 1ns/div~100s/div (1-2-5steps); ROLL: 100ms/div~100s/div | |||||||
Pre-Trigger | 10div maximum | |||||||
Post-Trigger | 1,000div | |||||||
Accuracy | 20 ppm over any 1 ms time interval | |||||||
Signal Acquisition System | ||||||||
Real Time Sample Rate | 2.5GSa/s | 5GSa/s | 2.5GSa/s | 5GSa/s | 5GSa/s | 5GSa/s | 4GSa/s | 4GSa/s |
Equivalent Time Sample Rate | 100GSa/s maximum for all models | |||||||
Record Length | 25k points | |||||||
Acquisition Mode | Normal, Average, Peak Detect, High resolution, Single Normal: Acquire sampled values Average: From 2 to 256 waveforms included in average Peak Detect: Catches glitches as narrow as 2ns at all sweep speeds Hi Res: Real-time boxcar averaging reduces random noise and increases vertical resolution | |||||||
X-Y Mode | ||||||||
X-axis input | Channel 1; Channel 3 | |||||||
Y-axis input | Channel 2; Channel 4 | |||||||
Phase Shift | 3 at 100kHz | |||||||
Cursors and Measurement | ||||||||
Cursors | Amplitude, Time, Gating available | |||||||
Automatic Measurement | 28 sets: Vpp, Vamp, Vavg, Vrms, Vhi, Vlo, Vmax, Vmin, Rise Preshoot/ Overshoot, Fall Preshoot/Overshoot, Freq, Period, Rise Time, Fall Time, Positive Width, Negative Width, Duty Cycle, Phase, eight different delay measurements (FRR, FRF, FFR, FFF, LRR, LRF, LFR, LFF) | |||||||
Cursors Measurement | V, T | |||||||
Auto Counter | 6digits, range from 2Hz minimum to the rated bandwidth | |||||||
Power Measurements (optional) | ||||||||
Power Quality Measurements | VRMS, V Crest Factor, Frequency, IRMS, I Crest Factor, True Power, Apparent Power, Reactive Power, Power Factor, Phase Angle. | |||||||
Harmonics | Freq, Mag, Mag rms, Phase, THD-F, THD-R, RMS | |||||||
Ripple Measurements | Vripple, Iripple | |||||||
In-rush Current | First peak, second peak | |||||||
Control Panel Functions | ||||||||
Autoset | Single-button, automatic setup of all channels for vertical, horizontal and trigger systems, with undo autoset | |||||||
Auto-Range | Allows users to quickly move from test point to test point without having to reset the oscilloscope for each test point | |||||||
Save Setup | 20 sets | |||||||
Save Waveform | 24 sets | |||||||
Display System | ||||||||
TFT LCD | 8″ TFT LCD SVGA color display (LED backlight) | |||||||
Display Resolution | 800 horizontal 600 vertical (SVGA) | |||||||
Interpolation | Sin(x)/x and equivalent time sampling | |||||||
Waveform Display | Dots, Vectors, Variable persistence, infinite persistence | |||||||
Display Graticule | 8 x 10 divisions | |||||||
Display Brightness | Adjustable | |||||||
Interface | ||||||||
RS-232C port | DB-9port | |||||||
USB port | 2 sets USB 2.0 high-speed host port; 1setUSB 2.0 high speed device port | |||||||
Ethernet | RJ-45 port, 10/100Mbps | |||||||
VGAVideoPort | DB-15port, SVGA monitor output | |||||||
Line Output | 3.5mm stereo output jack for Go/NoGo audio alarm | |||||||
GPIB(Optional) | USB to GPIB converter | |||||||
Go/NoGo BNC | Maximum 5V /10mA TTL open collector ouput | |||||||
Kensington Style Lock | Rear panel security slot connects to standard Kensington style lock | |||||||
Power Source | ||||||||
LineVoltageRange | AC 100V ~ 240V, 48Hz ~ 63Hz, Auto selection |
Accessory | |
User manual CD x 1 , Power cord x1 | |
GTP-151R | 150MHz(10:1) passive probe for GDS-3152/ 3154 (per channel) |
GTP-251R | 250MHz(10:1) passive probe for GDS-3252/ 3254 (per channel) |
GTP-351R | 350MHz(10:1) passive probe for GDS-3352/ 3354 (per channel) |
GTP-501R | 500MHz(10:1) passive probe for GDS-3502/ 3504 (per channel) |
Optional Accessories | |
GUG-001 | GPIB to USB adapter |
GTP-033A | 35MHz 1:1 passive probe |
GTP-352R | 350MHz(20:1) passive probe |
GDP-025 | 25MHz high voltage differential probe |
GDP-050 | 50MHz 25MHz high voltage differential probe |
GDP-100 | 100MHz 25MHz high voltage differential probe |
GCP-005 | 1kHz/5A Current probe |
GCP-020 | 10kHz/200A Current probe |
GCP-100 | 100KHz/100A Current probe |
GCP-530 | 50MHz/ 30A Current probe |
GCP-1030 | 100MHz/ 30A Current probe |
GCP-206P | Power supply for current probe (2 input channels) |
GCP-425P | Power supply for current probe (4 input channels) |
GTL-248 | GPIB Cable, Double Shielded, 2000mm |
GTL-251 | USB-GPIB Adapter, GPIB-USB-HS, USB 2.0, Hi-Speed USB compliance, 2000mm |
GSC-008 | Soft Carrying Case |
GTL-110 | Test lead, BNC to BNC connector |
GTL-232 | RS-232C cable, 9-pin female to 9-pin female, Null Modem for computer |
GTL-246 | USB 2.0 cable, A-B type cable 4P, 1800mm |
GRA-411 | Rack Adapter Panel |
GDB-03 | Oscilloscope Education and Training Kit |
GKT-100 | Deskew fixture |