Description |
- 2012-2014 top selling unit
- 9 kHz to 1.5 GHz Frequency Range
- Typical -135 dBm Displayed Average Noise Level (DANL)
- -80 dBc/Hz @10 kHz offset Phase Noise
- Total Amplitude Uncertainty <1.5 dB
- 10 Hz Minimum Resolution Bandwidth (RBW) (As of 4/1/2017 - Previously 100 Hz)
- Standard with Preamplifier and AM/FM Demodulation Function
- 1.5 GHz Tracking Generator
- 8 inch (800×480 pixels) high-definition display with clear, vivid, and easy to use graphical interface
- Complete connectivity with standard interfaces such as LAN, USB Host, USB Device and GPIB (optional)
- Compact size, light weight 4.25kg (9.4lbs)
| GSP-9300B is a 3GHz spectrum analyzer to meet basic RF measurement requirements. It provides the frequency stability of 0.025ppm; the aging rate of 1ppm/year; a built-in preamplifier; the base noise of -149dBm/Hz, and more than 20 measurement applications, including AM/FM modulation signal analysis, signal channel analysis, and CATV parameter test. While collocating with TG option, GSP-9300B can conduct frequency response or power linearity tests for components. | Series Key Features
- PR-01: AC voltage probe, 150kHz ~ 30MHz
- PR-02: Electric field probe, 30MHz ~ 3GHz
- ANT-04: Magnetic field probe, 30MHz ~ 3GHz
- ANT-05: Magnetic field probe, 30MHz ~ 3GHz
- ADP-002: Adaptor SMA(F) to N-type (M)
- GTL-303: RF testing cable SMA(M) to SMA(M)
GKT-008 EMI Near Probe Set comprises of four probes, including the PR-01, PR-02, ANT-04, and ANT-05. The antenna factors of these four probes are built in the EMC Pretest function of the GSP-9330 spectrum analyzer. ANT-04 and ANT-05 are EMI magnetic field probes, which can maximally sustain 50Vdc. ANT-04 and ANT-05 magnetic field probes will collocate with ADB-008 DC block to avoid damaging spectrum analyzer and the RF input terminal of DUT receiver. PR-01 is an AC voltage probe, which can maximally sustain CAT II, 300VAC, PR-01 AC voltage probe will collocate with GPL-5010 transient limiter and BNC (M) to SMA (F) adapter to avoid damaging spectrum analyzer and the RF input terminal of DUT reciever. PR-02 is an EMI electric field probe, which can maximally sustain CAT I 50V DC. PR-02 electric field probe will collocate with ADB-008 DC block to avoid damaging spectrum analyzer and the RF input terminal of DUT receiver. | Return Loss Bridge [GSP-Series]. Impedance : 50 ohms, N-Type Connector, Source/Load:Female, Couple:Male. 1GHz Return Loss Bridge Compatible with GSP-Series | | |
Additional information |
Weight |
15 lbs |
Dimensions |
16 × 8 × 8 in |
|
Weight |
10 lbs |
Dimensions |
14 × 8 × 10 in |
|
Weight |
3 lbs |
Dimensions |
6 × 10 × 4 in |
|
Weight |
2 lbs |
Dimensions |
4 × 4 × 4 in |
|
Weight |
2 lbs |
Dimensions |
9 × 7 × 1 in |
|
Weight |
2 lbs |
Dimensions |
6 × 10 × 4 in |
|