In Stock

Instek GLN-5040A Line Impedance Stabilization Networ – Line Impedance Stabilization Network [LISN] for GSP-9330 spectrum analyzer

Available for Quote

The GLN – 5040A Two Line V – Network is used for EMI testing. It provides stable impedance for the EUT terminals and the reference ground within the conducted emissions range. The GLN – 5040A also isolates the unwanted network signals from the power supply unit and only couples the disturbance voltage of the measured device to the receiver. The product’s performance is in compliance with the standard requirements of CISPR16 – 1 – 2 for V – networks with a simulated impedance of 50? H + 5 ?) || 50 ? in the frequency range of 9kHz to 30MHz. It uses standard BNC output connector with 50 ? output impedance to match any measurement devices such as receivers and spectrum analyzers.

View List
SKU: N_GW Instek GLN-5040A Category: Tag:

Quick Comparison

SettingsInstek GLN-5040A Line Impedance Stabilization Networ - Line Impedance Stabilization Network [LISN] for GSP-9330 spectrum analyzer removeGW Instek GPD-3303D 195W Triple-Output Programmable Linear DC Power Supply 30V , 3 A, 100mV, 10-milliamp Resolution removeGW Instek PLR 20-18 DC Power Supply, 20V, 18A, 360W Low Noise removeGW Instek GPE-1326 Multi-Output DC Power Supply, Single Channel, 192W, 0-32 VDC, 0-6A removeGW Instek GPE-2323 GPE-X323 Multi-Output DC Power Supply, 2 Channel, 192W, 0-32 VDC, 0-3A, Series/Parallel removeInstek PSU-03B Bus Bar for 4 units in parallel operation remove
Image
SKUN_GW Instek GLN-5040AN_GW Instek GPC-3030DN_GW Instek PLR 20-18N_GW Instek GPE-1326N_GW Instek GPE-2323N_GW Instek PSU-03B
Rating
PriceAvailable for QuoteAvailable for QuoteAvailable for QuoteAvailable for QuoteAvailable for QuoteAvailable for Quote
Stock
Availability
Add to cart

Add to Cart

Add to Cart

Add to Cart

Add to Cart

Add to Cart

Add to Cart

DescriptionThe GLN - 5040A Two Line V - Network is used for EMI testing. It provides stable impedance for the EUT terminals and the reference ground within the conducted emissions range. The GLN - 5040A also isolates the unwanted network signals from the power supply unit and only couples the disturbance voltage of the measured device to the receiver. The product's performance is in compliance with the standard requirements of CISPR16 - 1 - 2 for V - networks with a simulated impedance of 50? H + 5 ?) || 50 ? in the frequency range of 9kHz to 30MHz. It uses standard BNC output connector with 50 ? output impedance to match any measurement devices such as receivers and spectrum analyzers.0-30Vx2,0-3Ax2; 2.5V/3.3V/5V,3A, USB; 2 3/4 digit Three Independent Output : 30V/3A x 2, 2.5V/3.3V/5V/3A x 1 4 LED Display Sets : 3 Digits After Decimal Point Minimum Resolution : 100mV/10mA Digital Panel Control (Rotary Encoder Switch, Rubber Key With Indicator) Key-Lock User-Friendly Operation, Coarse/Fine Voltage Control 4 Panel Settings Save/Recall (Plus Factory Settings Recall) Output ON/OFF Tracking Series and Parallel Mode USB Device for Remote Control (Baud Rate 115200 bps Maximum) Free downloadable PC software Smart Cooling Fan Achieving Low Noise Warning Buzzer Light-Weight and Compact Design

Hybrid Linear, Low noise, 0-20V/0-18A, 360W

  • Output Voltage Rating: 20V
  • Output Power: 360W
  • Low Ripple and Noise (0.5mVrms/ 10mArms)
  • Fast transition recovery time (100us)
  • Maximum 2 units in series connections or 3 units in parallel connections
  • Select the setting digits for voltage and current (coarse/ fine volume control)
  • Panel Lock Function
  • 3 set of preset function
  • Output off timer function (Range: 1min to 1000hours & 59mins)
  • CC priority function (prevent overshoot & inrush current)
  • Sequence function of PC editing (Max.: 1000 steps/ Min. step period: 50ms)
  • Protection: OVP, UVP, OCP, remote sensing (Terminal open)
  • External Analog Control Function
  • PC Remote Interface (Standard): RS-232; (Optional): GPIB / USB / LAN
  • CE Compliance
192W Single Channel DC Power Supply GPE-1326 Single Channel, 192W Linear DC Power Supply 1 Independent Isolated Output 10mv min resolution 1ma min resolution 4.3 Inch LCD Display Setting & Read back Resolution 10mA / 1mA Output ON/OFF Analog Control (Remote I/O) for Output ON / OFF Set View function for checking an original V / I setting during output on Key Lock Function Tracking series and parallel operation Smart cooling fan achieving low noise Optional European Jack Type Terminal192W Two Channel DC Power Supply GPE-2323 2 Channels, 192W Linear DC Power Supply 2 Independent Isolated Output 10mv min resolution 1ma min resolution 4.3 Inch LCD Display Setting & Read back Resolution 10mA / 1mA Output ON/OFF Analog Control (Remote I/O) for Output ON / OFF Set View function for checking an original V / I setting during output on Key Lock Function Tracking series and parallel operation Smart cooling fan achieving low noise Optional European Jack Type Terminal
Content
Weight12151515152
Dimensions23 × 18 × 11 in18 × 12 × 10 in18 × 12 × 10 in20 × 15 × 11 in18 × 12 × 10 in4 × 6 × 2 in
Additional information
Weight 12 lbs
Dimensions 23 × 18 × 11 in
Weight 15 lbs
Dimensions 18 × 12 × 10 in
Weight 15 lbs
Dimensions 18 × 12 × 10 in
Weight 15 lbs
Dimensions 20 × 15 × 11 in
Weight 15 lbs
Dimensions 18 × 12 × 10 in
Weight 2 lbs
Dimensions 4 × 6 × 2 in