Description | The GLN - 5040A Two Line V - Network is used for EMI testing. It provides stable impedance for the EUT terminals and the reference ground within the conducted emissions range. The GLN - 5040A also isolates the unwanted network signals from the power supply unit and only couples the disturbance voltage of the measured device to the receiver. The product's performance is in compliance with the standard requirements of CISPR16 - 1 - 2 for V - networks with a simulated impedance of 50? H + 5 ?) || 50 ? in the frequency range of 9kHz to 30MHz. It uses standard BNC output connector with 50 ? output impedance to match any measurement devices such as receivers and spectrum analyzers. | 54W DC Linear Power Supply 0-18V, 0-3A DIGITAL Display
0-3A DIGITAL
Light and Compact Design
0.01% High Regulation
Constant Voltage and Constant Current Operation
Remote Control for External Programmability
Internal Select for Continuous or Dynamic Load
Low Ripple and Noise
Overload and Reverse Polarity Protection
Series or Parallel Operation | 300W DC Linear Power Supply 0-300V, 0-1A
0-300V, 0-1A
0.01% High Regulation
Constant Voltage and Constant Current Operation
Internal Select for Continuous or Dynamic Load
Low Ripple and Noise
Overload and Reverse Polarity Protection
3 1/2 Digit 0.5" LED Display | 350W DC Linear Power Supply 0-35V, 0-10A
0-35V, 0-10A
0.01% High Regulation
Constant Voltage and Constant Current Operation
Internal Select for Continuous or Dynamic Load
Low Ripple and Noise
Overload and Reverse Polarity Protection
3 1/2 Digit 0.5" LED Display | 90W DC Linear Power Supply 0-30V, 0-3A DIGITAL Display
- 0-3A DIGITAL
- Light and Compact Design
- 0.01% High Regulation
- Constant Voltage and Constant Current Operation
- Remote Control for External Programmability
- Internal Select for Continuous or Dynamic Load
- Low Ripple and Noise
- Overload and Reverse Polarity Protection
- Series or Parallel Operation
| Hybrid Linear, Low noise, 0-20V/0-18A, 360W
- Output Voltage Rating: 20V
- Output Power: 360W
- Low Ripple and Noise (0.5mVrms/ 10mArms)
- Fast transition recovery time (100us)
- Maximum 2 units in series connections or 3 units in parallel connections
- Select the setting digits for voltage and current (coarse/ fine volume control)
- Panel Lock Function
- 3 set of preset function
- Output off timer function (Range: 1min to 1000hours & 59mins)
- CC priority function (prevent overshoot & inrush current)
- Sequence function of PC editing (Max.: 1000 steps/ Min. step period: 50ms)
- Protection: OVP, UVP, OCP, remote sensing (Terminal open)
- External Analog Control Function
- PC Remote Interface (Standard): RS-232; (Optional): GPIB / USB / LAN
- CE Compliance
|
Additional information |
Weight |
12 lbs |
Dimensions |
23 × 18 × 11 in |
|
Weight |
15 lbs |
Dimensions |
18 × 12 × 10 in |
|
Weight |
15 lbs |
Dimensions |
18 × 12 × 10 in |
|
Weight |
15 lbs |
Dimensions |
18 × 12 × 10 in |
|
Weight |
15 lbs |
Dimensions |
18 × 12 × 10 in |
|
Weight |
15 lbs |
Dimensions |
18 × 12 × 10 in |
|