Series Key Features

  • PR-01: AC voltage probe, 150kHz ~ 30MHz
  • PR-02: Electric field probe, 30MHz ~ 3GHz
  • ANT-04: Magnetic field probe, 30MHz ~ 3GHz
  • ANT-05: Magnetic field probe, 30MHz ~ 3GHz
  • ADP-002: Adaptor SMA(F) to N-type (M)
  • GTL-303: RF testing cable SMA(M) to SMA(M)

GKT-008 EMI Near Probe Set comprises of four probes, including the PR-01, PR-02, ANT-04, and ANT-05. The antenna factors of these four probes are built in the EMC Pretest function of the GSP-9330 spectrum analyzer. ANT-04 and ANT-05 are EMI magnetic field probes, which can maximally sustain 50Vdc. ANT-04 and ANT-05 magnetic field probes will collocate with ADB-008 DC block to avoid damaging spectrum analyzer and the RF input terminal of DUT receiver. PR-01 is an AC voltage probe, which can maximally sustain CAT II, 300VAC, PR-01 AC voltage probe will collocate with GPL-5010 transient limiter and BNC (M) to SMA (F) adapter to avoid damaging spectrum analyzer and the RF input terminal of DUT reciever. PR-02 is an EMI electric field probe, which can maximally sustain CAT I 50V DC. PR-02 electric field probe will collocate with ADB-008 DC block to avoid damaging spectrum analyzer and the RF input terminal of DUT receiver.

View List
SKU: N_GW Instek GKT-008 Category: Tag:

Quick Comparison

SettingsGKT-008 EMI Near Field Probe Set Test Lead / Probe Kit, ANT-04, ANT-05, ADP-002, GTL-303, PR-01, PR-02 removeInstek PLR 36-10 DC Power Supply, 36V, 10A, 360W Low Noise removeGW Instek SFG-1003 DDS Function Generator with 6 Digit LED Display, 0.1Hz to 3MHz Frequency removeGW Instek GPE-3323 GPE-X323 Multi-Output DC Power Supply, 3 Channel, 217W, 0-32 VDC, 0-3A, 5V/5A removeGW Instek GPD-2303S 180W Dual-Output Programmable Linear DC Power Supply, 30V DC, 3 Amp removeInstek GPD-3303S 195W Triple-Output Programmable Linear DC Power Supply, 30V DC, 3 Amp, 1mV, 1-milliamp Resolution remove
Image
SKUN_GW Instek GKT-008N_GW Instek PLR 36-10N_GW Instek SFG-1003N_GW Instek GPE-3323N_GW Instek GPD-2303SN_GW Instek GPD-3303S
Rating
PriceAvailable for QuoteAvailable for QuoteAvailable for QuoteAvailable for QuoteAvailable for QuoteAvailable for Quote
Stock
Availability
Add to cart

Add to Cart

Add to Cart

Add to Cart

Add to Cart

Add to Cart

Add to Cart

DescriptionSeries Key Features
  • PR-01: AC voltage probe, 150kHz ~ 30MHz
  • PR-02: Electric field probe, 30MHz ~ 3GHz
  • ANT-04: Magnetic field probe, 30MHz ~ 3GHz
  • ANT-05: Magnetic field probe, 30MHz ~ 3GHz
  • ADP-002: Adaptor SMA(F) to N-type (M)
  • GTL-303: RF testing cable SMA(M) to SMA(M)
GKT-008 EMI Near Probe Set comprises of four probes, including the PR-01, PR-02, ANT-04, and ANT-05. The antenna factors of these four probes are built in the EMC Pretest function of the GSP-9330 spectrum analyzer. ANT-04 and ANT-05 are EMI magnetic field probes, which can maximally sustain 50Vdc. ANT-04 and ANT-05 magnetic field probes will collocate with ADB-008 DC block to avoid damaging spectrum analyzer and the RF input terminal of DUT receiver. PR-01 is an AC voltage probe, which can maximally sustain CAT II, 300VAC, PR-01 AC voltage probe will collocate with GPL-5010 transient limiter and BNC (M) to SMA (F) adapter to avoid damaging spectrum analyzer and the RF input terminal of DUT reciever. PR-02 is an EMI electric field probe, which can maximally sustain CAT I 50V DC. PR-02 electric field probe will collocate with ADB-008 DC block to avoid damaging spectrum analyzer and the RF input terminal of DUT receiver.

Hybrid Linear, Low noise, 0-36V/0-10A, 360W

  • Output Voltage Rating: 36V
  • Output Power: 360W
  • Low Ripple and Noise (0.5mVrms/ 10mArms)
  • Fast transition recovery time (100us)
  • Maximum 2 units in series connections or 3 units in parallel connections
  • Select the setting digits for voltage and current (coarse/ fine volume control)
  • Panel Lock Function
  • 3 set of preset function
  • Output off timer function (Range: 1min to 1000hours & 59mins)
  • CC priority function (prevent overshoot & inrush current)
  • Sequence function of PC editing (Max.: 1000 steps/ Min. step period: 50ms)
  • Protection: OVP, UVP, OCP, remote sensing (Terminal open)
  • External Analog Control Function
  • PC Remote Interface (Standard): RS-232; (Optional): GPIB / USB / LAN
  • CE Compliance
SFG-1000 Series, an economic function generator with high accuracy and high stability output, is designed based on the DDS (Direct Digital Synthesis) technology embedded in a large scale FPGA. The frequency range of 3MHz and the output waveform selection as Sine, Square, Triangle and TTL of SFG-1000 Series adequately provide the fundamental features to ensure high confidence for the test results. The DDS technology at an affordable price gives a high-value solution to the users who need a signal source for accurate but unsophisticated measurement applications.217W 3 Channel DC Power Supply GPE-3323 3 Channels, 217W Linear DC Power Supply 3 Independent Isolated Output 10mv min resolution 1ma min resolution 4.3 Inch LCD Display Setting & Read back Resolution 10mA / 1mA Output ON/OFF Analog Control (Remote I/O) for Output ON / OFF Set View function for checking an original V / I setting during output on Key Lock Function Tracking series and parallel operation Smart cooling fan achieving low noise Optional European Jack Type Terminal180W, 2ch Output DC Programmable Power Supply 4 Outputs for GPD-4303S High Resolution Display 1mV / 1mA (GPD-X303S) CH1/CH2 Output: 30V / 3A CH3 Selectable Output: 5V/3A ; 5.001V-10V /1A (GPD-4303S) CH4 Output: 5V / 1A (GPD-4303S) Auto Series / Parallel Tracking Mode Digital Panel ControlRotary Encoder Switch and Rubber Key with Backlight 4 Sets SAVE / RECALL panel setting User Friendly Operation, Coarse and Fine Voltage Control Warning Buzzer Output On / Off Switch USB Device for Remote Control (Baud Rate 115200 bps Maximum) Free downloadable PC software Smart Cooling Fan with Low Noise Safety Design: Reverse Polarity, Overload Protection0-30Vx2,0-3Ax2; 2.5V/3.3V/5V,3A, USB; 4 3/4 digit Three Independent Output : 30V/3A x 2, 2.5V/3.3V/5V/3A x 1 4 LED Display Sets : 3 Digits After Decimal Point Minimum Resolution : 1mV/1mA Digital Panel Control (Rotary Encoder Switch, Rubber Key With Indicator) Key-Lock User-Friendly Operation, Coarse/Fine Voltage Control 4 Panel Settings Save/Recall (Plus Factory Settings Recall) Output ON/OFF Tracking Series and Parallel Mode USB Device for Remote Control (Baud Rate 115200 bps Maximum) Free downloadable PC software Smart Cooling Fan Achieving Low Noise Warning Buzzer Light-Weight and Compact Design
Content
Weight3156151518
Dimensions6 × 10 × 4 in18 × 12 × 10 in15 × 12 × 6 in18 × 12 × 10 in18 × 12 × 10 in18 × 12 × 10 in
Additional information
Weight 3 lbs
Dimensions 6 × 10 × 4 in
Weight 15 lbs
Dimensions 18 × 12 × 10 in
Weight 6 lbs
Dimensions 15 × 12 × 6 in
Weight 15 lbs
Dimensions 18 × 12 × 10 in
Weight 15 lbs
Dimensions 18 × 12 × 10 in
Weight 18 lbs
Dimensions 18 × 12 × 10 in