GW Instek GLP-1A Logic Probe and Pulser, 4VDC to 18VDC Operating Voltage, 50MHz Maximum Input Frequency
Available for Quote
The GLP-1A logic pulser can be used to perform in-circuit testing of TTL, CMOS, and many other logic devices at a maximum of 50MHz. The GLP-1A is enhanced with a logic probe function with a minimum detectable pulse width of 10 ns, providing enough sensitivity for most applications. A Short 10 sec pulse width assures that no damage will occur to circuits whilst testing. With a weight less than 50g, a non-slip grip, and an external sync input, GLP-1A provides comfort and reliability for various troubleshooting tasks.
Quick Comparison
| Settings | GW Instek GLP-1A Logic Probe and Pulser, 4VDC to 18VDC Operating Voltage, 50MHz Maximum Input Frequency remove | GW Instek 40Hz-10KHz/20A Current Probe remove | Probe Master 4236 Differential Probe, 50MHz, 100X, 1400V remove | [Renew] Tektronix TPP1000 1 GHz 10x Passive Voltage Probe remove | Probe Master 4901-1KRA Passive Voltage Probe with Readout, 150MHz, 1X/10X, 600V, 3.5ft, DELUXE KIT remove | Probe Master 4231 Differential Probe, 25MHz, 20X/200X, 1400V remove | ||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Image | ![]() | ![]() | ![]() | ![]() | ![]() | ![]() | ||||||||||||||||||
| SKU | N_GW Instek GLP-1A | N_GW Instek GCP-020 | N_Probe Master 4236 | Tektronix TPP1000 | N_Probe Master 4901-1KRA | N_Probe Master 4231 | ||||||||||||||||||
| Rating | ||||||||||||||||||||||||
| Price | Available for Quote | Available for Quote | Available for Quote | Available for Quote | Available for Quote | Available for Quote | ||||||||||||||||||
| Stock | ||||||||||||||||||||||||
| Availability | ||||||||||||||||||||||||
| Add to cart | ||||||||||||||||||||||||
| Description | The GLP-1A logic pulser can be used to perform in-circuit testing of TTL, CMOS, and many other logic devices at a maximum of 50MHz. The GLP-1A is enhanced with a logic probe function with a minimum detectable pulse width of 10 ns, providing enough sensitivity for most applications. A Short 10 sec pulse width assures that no damage will occur to circuits whilst testing. With a weight less than 50g, a non-slip grip, and an external sync input, GLP-1A provides comfort and reliability for various troubleshooting tasks. | |||||||||||||||||||||||
| Content | Current probe compatible with oscilloscope series: GDS-3000/2000A/1000A-U. No battery/power supply required. |
|
| |||||||||||||||||||||
| Weight | 1 | 2 | 1 | 1 | 1 | 0.3 | ||||||||||||||||||
| Dimensions | 6 × 8 × 4 in | 8 × 10 × 6 in | N/A | N/A | N/A | 7 × 3 × 2 in | ||||||||||||||||||
| Additional information |
|
|
|
|
|
|









