Description
- Voltage Rating: 800V, Output Power Rating: 720W
- 1/2, 1/3, 1/6 Rack Mount Size Design (EIA/JIS Standard) for 360W/720W/1080W
- Standard Interface: LAN,USB,Analog Control Interface
- Optional Interface: GPIB-USB Adaptor
- LabView Driver
- Constant Power Output for Multiple Range (V&I) Operation
- CV/CC Priority; Particularly Suitable for the Battery and LED Industry
- Adjustable Slew Rate
- Series Operation: Up to 2 units (30V, 80V, 160V models only)
- Parallel Operation: Up to 3 units
- High Efficiency and High Power Density
Manufacturer Specs
Model | PSW 250-4.5 | PSW 250-9 | PSW 250-13.5 | PSW 800-1.44 | PSW 800-2.88 | PSW 800-4.32 |
OUTPUT RATING | ||||||
Voltage | 0 ~ 250V | 0 ~ 800V | ||||
Current | 0 ~ 4.5A | 0 ~ 9A | 0 ~ 13.5A | 0 ~ 1.44A | 0 ~ 2.88A | 0 ~ 4.32A |
Power | 360W | 720W | 1080W | 360W | 720W | 1080W |
REGULATION (CV) | ||||||
Load | 0.05% of rating + 5mV | |||||
Line | 0.05% of rating + 3mV | |||||
REGULATION (CC) | ||||||
Load | 0.1% of rating + 5mA | |||||
Line | 0.1% of rating + 5mA | |||||
CV p-p | 80mV | 100mV | 120mV | 150mV | 200mV | 200mV |
CV rms | 15mV | 30mV | ||||
CC rms | 10mA | 20mA | 30mA | 5mA | 10mA | 15mA |
Voltage | 0.1%+200mV | 0.1%+400mV | ||||
Current | 0.1%+5mA | 0.1%+10mA | 0.1%+15mA | 0.1%+2mA | 0.1%+4mA | 0.1%+6mA |
READBACK ACCURACY | ||||||
Voltage | 0.1%+200mV | 0.1%+400mV | ||||
Current | 0.1%+5mA | 0.1%+10mA | 0.1%+15mA | 0.1%+2mA | 0.1%+4mA | 0.1%+6mA |
RESPONSE TIME | ||||||
Raise Time | 100ms | 150ms | ||||
Fall Time(Full load) | 150ms | 300ms | ||||
Fall Time(No load) | 1200ms | 2000ms | ||||
Load Transient Recover Time(Load change from 50 to 100%) | 2ms | |||||
PROGRAMMING RESOLUTION (By PC Remote Control Mode) | ||||||
Voltage | 5mV | 14mV | ||||
1mA | ||||||
MEASUREMENT RESOLUTION (By PC Remote Control Mode) | ||||||
Voltage | 5mV | 14mV | ||||
1mA | ||||||
SERIES AND PARALLEL CAPABILITY | ||||||
Parallel Operation | Up to 3 units including the master unit | |||||
Series Operation | N/A | |||||
PROTECTION FUNCTION | ||||||
OVP | 10% to 110% of rated output voltage range | |||||
OCP | 10% to 110% of rated output current range | |||||
OHP | Activated by elecated internal temperature | |||||
FRONT PANEL DISPLAY ACCURACY | ||||||
Voltage | 0.1% ± 2 digits | 0.1% ± 4 digits | ||||
Current | 0.1% ± 5 digits | 0.1% ± 10 digits | 0.1% ± 20 digits | 0.1% ± 2 digits | 0.1% ± 4 digits | 0.1% ± 6 digits |
ENVIRONMENT CONDITION | ||||||
Operation Temp | 0°C to 50°C | |||||
Storage Temp | —25°C to 70°C | |||||
Operating Humidity | 20% to 85% RH | |||||
Storage Humidity | 90% RH or Less | |||||
TEMP COEFFICIENT( after 30 minutes warm up) | ||||||
Voltage | 100ppm/°C | |||||
Current | 200ppm/°C | |||||
OTHER | ||||||
Analog Control | Yes | |||||
Interface | USB/LAN/GPIB(Option) | |||||
FAN | With thermal sensing control | |||||
Power Source | 85VAC ~ 265VAC, 50/60Hz, Single phase | |||||
Dimension & Weight | 71(W) x 124(H) x 350(D)mm; Approx. 3kg |
142.5(W) x 124(H) x 350(D)mm; Approx. 5kg |
214(W) x 124(H) x 350(D)mm; Approx. 7kg |
71(W) x 124(H) x 350(D)mm; Approx. 3kg |
142.5(W) x 124(H) x 350(D)mm; Approx. 5kg |
214(W) x 124(H) x 350(D)mm; Approx. 7kg |
PSW-360W | |||||||
Model | PSW | 30-36 | 80-13.5 | 160-7.2 | 250-4.5 | 800-1.44 | |
Rated Output Voltage | V | 30 | 80 | 160 | 250 | 800 | |
Rated Output Current | A | 36 | 13.5 | 7.2 | 4.5 | 1.44 | |
Rated Output Power | W | 360 | 360 | 360 | 360 | 360 | |
Power Ratio | — | 3 | 3 | 3.2 | 3.125 | 3.2 | |
Constant Voltage Mode | PSW | 30-36 | 80-13.5 | 160-7.2 | 250-4.5 | 800-1.44 | |
Line Regulation (*1) | mV | 18 | 43 | 83 | 128 | 403 | |
Load Regulation (*2) | mV | 20 | 45 | 85 | 130 | 405 | |
Ripple and Noise (*3) | |||||||
p-p (*4) | mV | 60 | 60 | 60 | 80 | 150 | |
r.m.s (*5) | mV | 7 | 7 | 12 | 15 | 30 | |
Temperature coefficient | ppm/°C | 100ppm/°C of rated output voltage, after a 30 minute warm-up. | |||||
Remote sense compensation voltage | V/wire | 0.6 | 0.6 | 0.6 | 1 | 1 | |
Rise Time (*6) | |||||||
Rated Load | ms | 50 | 50 | 100 | 100 | 150 | |
No Load | ms | 50 | 50 | 100 | 100 | 150 | |
Fall Time (*7) | |||||||
Rated Load | ms | 50 | 50 | 100 | 150 | 300 | |
No Load | ms | 500 | 500 | 1000 | 1200 | 2000 | |
Transient response time (*8) | ms | 1 | 1 | 2 | 2 | 2 | |
Constant Current Mode | PSW | 30-36 | 80-13.5 | 160-7.2 | 250-4.5 | 800-1.44 | |
Line regulation (*1) | mA | 41 | 18.5 | 12.2 | 9.5 | 6.44 | |
Load regulation (*9) | mA | 41 | 18.5 | 12.2 | 9.5 | 6.44 | |
Ripple and noise | |||||||
r.m.s (*5 ) | mA | 72 | 27 | 15 | 10 | 5 | |
Temperature coefficient | ppm/°C | 200ppm/°C of rated output current, after a 30 minute warm-up. | |||||
Protection Function | PSW | 30-36 | 80-13.5 | 160-7.2 | 250-4.5 | 800-1.44 | |
Over voltage protection (OVP) | |||||||
Setting range | V | 3-33 | 8-88 | 16-176 | 20-275 | 20-880 | |
Setting accuracy | ± (2% of rated output voltage) | ||||||
Over current protection (OCP) | |||||||
Setting range | A | 3.6-39.6 | 1.35-14.85 | 0.72-7.92 | 0.45-4.95 | 0.144-1.584 | |
Setting accuracy | ± (2% of rated output current) | ||||||
Over temperature protection (OTP) | |||||||
Operation | Turn the output off. | ||||||
Low AC input protection (AC-FAIL) | |||||||
Operation | Turn the output off. | ||||||
Power limit (POWER LIMIT) | |||||||
Operation | Over power limit. | ||||||
Value (fixed) | Approx. 105% of rated output power | ||||||
Front Panel | PSW | 30-36 | 80-13.5 | 160-7.2 | 250-4.5 | 800-1.44 | |
Display, 4 digits | |||||||
Voltage accuracy 0.1% + | mV | 20 | 20 | 100 | 200 | 400 | |
Current accuracy 0.1% + | mA | 40 | 20 | 5 | 5 | 2 | |
Programming and Measurement (Interface) | PSW | 30-36 | 80-13.5 | 160-7.2 | 250-4.5 | 800-1.44 | |
Voltage programming accuracy 0.1% + | mV | 10 | 10 | 100 | 200 | 400 | |
Current programming accuracy 0.1% + | mA | 30 | 10 | 5 | 5 | 2 | |
Voltage programming resolution | mV | 1 | 2 | 3 | 5 | 14 | |
Current programming resolution | mA | 1 | 1 | 1 | 1 | 1 | |
Voltage measurement accuracy 0.1% + | mV | 10 | 10 | 100 | 200 | 400 | |
Current measurement accuracy 0.1% + | mA | 30 | 10 | 5 | 5 | 2 | |
Voltage measurement resolution | mV | 1 | 2 | 3 | 5 | 14 | |
Current measurement resolution | mA | 1 | 1 | 1 | 1 | 1 | |
PSW-720W | |||||||
Model | PSW | 30-72 | 80-27 | 160-14.4 | 250-9 | 800-2.88 | |
Rated Output Voltage | V | 30 | 80 | 160 | 250 | 800 | |
Rated Output Current | A | 72 | 27 | 14.4 | 9 | 2.88 | |
Rated Output Power | W | 720 | 720 | 720 | 720 | 720 | |
Power Ratio | — | 3 | 3 | 3.2 | 3.125 | 3.2 | |
Constant Voltage Mode | PSW | 30-72 | 80-27 | 160-14.4 | 250-9 | 800-2.88 | |
Line Regulation (*1) | mV | 18 | 43 | 83 | 128 | 403 | |
Load Regulation (*2) | mV | 20 | 45 | 85 | 130 | 405 | |
Ripple and Noise (*3) | |||||||
p-p (*4) | mV | 80 | 80 | 80 | 100 | 200 | |
r.m.s (*5) | mV | 11 | 11 | 15 | 15 | 30 | |
Temperature coefficient | ppm/°C | 100ppm/°C of rated output voltage, after a 30 minute warm-up. | |||||
Remote sense compensation voltage | V/wire | 0.6 | 0.6 | 0.6 | 1 | 1 | |
Rise Time (*6) | |||||||
Rated Load | ms | 50 | 50 | 100 | 100 | 150 | |
No Load | ms | 50 | 50 | 100 | 100 | 150 | |
Fall Time (*7) | |||||||
Rated Load | ms | 50 | 50 | 100 | 150 | 300 | |
No Load | ms | 500 | 500 | 1000 | 1200 | 2000 | |
Transient response time (*8) | ms | 1 | 1 | 2 | 2 | 2 | |
Constant Current Mode | PSW | 30-72 | 80-27 | 160-14.4 | 250-9 | 800-2.88 | |
Line regulation (*1) | mA | 77 | 32 | 19.4 | 14 | 7.88 | |
Load regulation (*9) | mA | 77 | 32 | 19.4 | 14 | 7.88 | |
Ripple and noise | |||||||
r.m.s (*5 ) | mA | 144 | 54 | 30 | 20 | 10 | |
Temperature coefficient | ppm/°C | 200ppm/°C of rated output current, after a 30 minute warm -up. | |||||
Protection Function | PSW | 30-72 | 80-27 | 160-14.4 | 250-9 | 800-2.88 | |
Over voltage protection (OVP) | |||||||
Setting range | V | 3-33 | 8-88 | 16-176 | 20-275 | 20-880 | |
Setting accuracy | ± (2% of rated output voltage) | ||||||
Over current protection (OCP) | |||||||
Setting range | A | 5-79.2 | 2.7-29.7 | 1.44-15.84 | 0.9-9.9 | 0.288-3.168 | |
Setting accuracy | ± (2% of rated output current) | ||||||
Over temperature protection (OTP) | |||||||
Operation | Turn the output off. | ||||||
Low AC input protection (AC-FAIL) | |||||||
Operation | Turn the output off. | ||||||
Power limit (POWER LIMIT) | |||||||
Operation | Over power limit. | ||||||
Value (fixed) | Approx. 105% of rated output power | ||||||
Front Panel | PSW | 30-72 | 80-27 | 160-14.4 | 250-9 | 800-2.88 | |
Display, 4 digits | |||||||
Voltage accuracy 0.1% + | mV | 20 | 20 | 100 | 200 | 400 | |
Current accuracy 0.1% + | mA | 70 | 40 | 30 | 10 | 4 | |
Programming and Measurement (Interface) | PSW | 30-72 | 80-27 | 160-14.4 | 250-9 | 800-2.88 | |
Voltage programming accuracy 0.1% + | mV | 10 | 10 | 100 | 200 | 400 | |
Current programming accuracy 0.1% + | mA | 60 | 30 | 15 | 10 | 4 | |
Voltage programming resolution | mV | 1 | 2 | 3 | 5 | 14 | |
Current programming resolution | mA | 2 | 2 | 2 | 1 | 1 | |
Voltage measurement accuracy 0.1% + | mV | 10 | 10 | 100 | 200 | 400 | |
Current measurement accuracy 0.1% + | mA | 60 | 30 | 15 | 10 | 4 | |
Voltage measurement resolution | mV | 1 | 2 | 3 | 5 | 14 | |
Current measurement resolution | mA | 2 | 2 | 2 | 1 | 1 | |
PSW-1080W | |||||||
Model | PSW | 30-108 | 80-40.5 | 160-21.6 | 250-13.5 | 800-4.32 | |
Rated Output Voltage | V | 30 | 80 | 160 | 250 | 800 | |
Rated Output Current | A | 108 | 40.5 | 21.6 | 13.5 | 4.32 | |
Rated Output Power | W | 1080 | 1080 | 1080 | 1080 | 1080 | |
Power Ratio | — | 3 | 3 | 3.2 | 3.125 | 3.2 | |
Constant Voltage Mode | PSW | 30-108 | 80-40.5 | 160-21.6 | 250-13.5 | 800-4.32 | |
Line Regulation (*1) | mV | 18 | 43 | 83 | 128 | 403 | |
Load Regulation (*2) | mV | 20 | 45 | 85 | 130 | 405 | |
Ripple and Noise (*3) | |||||||
p-p (*4) | mV | 100 | 100 | 100 | 120 | 200 | |
r.m.s (*5) | mV | 14 | 14 | 20 | 15 | 30 | |
Temperature coefficient | ppm/°C | 100ppm/°C of ra ted output voltage, after a 30 minute warm-up. | |||||
Remote sense compensation voltage | V/wire | 0.6 | 0.6 | 0.6 | 1 | 1 | |
Rise Time (*6) | |||||||
Rated Load | ms | 50 | 50 | 100 | 100 | 150 | |
No Load | ms | 50 | 50 | 100 | 100 | 150 | |
Fall Time (*7) | |||||||
Rated Load | ms | 50 | 50 | 100 | 150 | 300 | |
No Load | ms | 500 | 500 | 1000 | 1200 | 2000 | |
Transient response time (*8) | ms | 1 | 1 | 2 | 2 | 2 | |
Constant Current Mode | PSW | 30-108 | 80-40.5 | 160-21.6 | 250-13.5 | 800-4.32 | |
Line regulation (*1) | mA | 113 | 45.5 | 26.6 | 18.5 | 9.32 | |
Load regulation (*9) | mA | 113 | 45.5 | 26.6 | 18.5 | 9.32 | |
Ripple and noise | |||||||
r.m.s (*5 ) | mA | 216 | 81 | 45 | 30 | 15 | |
Temperature coefficient | ppm/°C | 200ppm/°C of rated output current, after a 30 minute warm-up . | |||||
Protection Function | PSW | 30-108 | 80-40.5 | 160-21.6 | 250-13.5 | 800-4.32 | |
Over voltage protection (OVP) | |||||||
Setting range | V | 3-33 | 8-88 | 16-176 | 20-275 | 20-880 | |
Setting accuracy | ± (2% of rated output voltage) | ||||||
Over current protection (OCP) | |||||||
Setting range | A | 5-118.8 | 4.05-44.55 | 2.16-23.76 | 1.35-14.85 | 0.432-4.752 | |
Setting accuracy | ± (2% of rated output current) | ||||||
Over temperature protection (OTP) | |||||||
Operation | Turn the output off. | ||||||
Low AC input protection (AC-FAIL) | |||||||
Operation | Turn the output off. | ||||||
Power limit (POWER LIMIT) | |||||||
Operation | Over power limit. | ||||||
Value (fixed) | Approx. 105% of rated output power | ||||||
Front Panel | PSW | 30-108 | 80-40.5 | 160-21.6 | 250-13.5 | 800-4.32 | |
Display, 4 digits | |||||||
Voltage accuracy 0.1% + | mV | 20 | 20 | 100 | 200 | 400 | |
Current accuracy 0.1% + | mA | 100 | 50 | 30 | 20 | 6 | |
Programming and Measurement (Interface) | PSW | 30-108 | 80-40.5 | 160-21.6 | 250-13.5 | 800-4.32 | |
Voltage programming accuracy 0.1% + | mV | 10 | 10 | 100 | 200 | 400 | |
Current programming accuracy 0.1% + | mA | 100 | 40 | 20 | 15 | 6 | |
Voltage programming resolution | mV | 1 | 2 | 3 | 5 | 14 | |
Current programming resolution | mA | 3 | 3 | 3 | 1 | 1 | |
Voltage measurement accuracy 0.1% + | mV | 10 | 10 | 100 | 200 | 400 | |
Current measurement accuracy 0.1% + | mA | 100 | 40 | 20 | 15 | 6 | |
Voltage measurement resolution | mV | 1 | 2 | 3 | 5 | 14 | |
Current measurement resolution | mA | 3 | 3 | 3 | 1 | 1 | |
Common Specification | |||||||
Input Characteristics | PSW | 30V | 80V | 160V | 250V | 800V | |
Nominal input rating | 100Vac to 240Vac, 50Hz to 60Hz, single phase | ||||||
Input voltage range | 85Vac ~ 265Vac | ||||||
Input voltage range | 47Hz ~ 63Hz | ||||||
Maximum input current | |||||||
100Vac | A | 360W: 5A, 720W: 10A, 1080W: 15A | |||||
200Vac | A | 360W: 2.5A, 720W: 5A, 1080W: 7.5A | |||||
Inrush current | A | < 25A for 360W, < 50A for 720W, < 75A for 1080W | |||||
Maximum input power | VA | 360W: 500VA, 720W: 1000VA, 1080W: 1500VA | |||||
Power factor | |||||||
100Vac | 0.99 | ||||||
200Vac | 0.97 | ||||||
Efficiency | |||||||
100Vac | % | 77 | 78 | 79 | 79 | 80 | |
200Vac | % | 79 | 80 | 81 | 81 | 82 | |
Hold-up time | 20ms or greater | ||||||
Analog Programming and Monitoring | PSW | 30V | 80V | 160V | 250V | 800V | |
External voltage control output voltage | Accuracy and linearity: ±0.5% of rated output voltage. | ||||||
External voltage control output current | Accuracy and linearity: ±1% of rated output current. | ||||||
External resistor control output voltage | Accuracy and linearity: ±1.5% of rated output voltage. | ||||||
External resistor control output current | Accuracy and linearity: ±1.5% of rated output current. | ||||||
Output voltage monitor | |||||||
Accuracy | % | ±1 | ±1 | ±1 | ±2 | ±2 | |
Output current monitor | |||||||
Accuracy | % | ±1 | ±1 | ±1 | ±2 | ±2 | |
Shutdown control | Turns the output off with a LOW (0V to 0.5V) or short-circuit. | ||||||
Output on/off control | Possible logic selections: Turn the output on using a LOW (0V to 0.5V) or short-circuit, turn the output off using a HIGH (4.5V to 5V) or open-circuit. Turn the output on using a HIGH (4.5V to 5V) or open-circuit, turn the output off using a LOW (0V to 0.5V) or short-circuit. |
||||||
CV/CC/ALM/PWR ON/OUT ON indicator | Photocoupler open collector output; Maximum voltage 30V, maximum sink current 8mA. | ||||||
Series and Parallel Capability | PSW | 30V | 80V | 160V | 250V | 800V | |
Parallel number | Units | 3 | 3 | 3 | 3 | 3 | |
Series Number | Units | 2 | 2 | 2 | None | None | |
Front Panel | |||||||
Indications | GREEN LED’s: CV, CC, VSR, ISR, DLY, RMT, 20, 40, 60, 80, 100, %W, W, V, A RED LED’s: ALM |
||||||
Buttons | Function, OVP/OCP, Set, Test, Lock/Local, PWR DSPL, Output | ||||||
Knobs | Voltage, Current | ||||||
USB port | Type A USB connector | ||||||
Interface Capabilities | |||||||
USB | TypeA: Host, TypeB: Slave, Speed: 1.1/2.0, USB Class: CDC(Communications Device Class) | ||||||
LAN | MAC Address, DNS IP Address, User Password, Gateway IP Address, Instrument IP Address, Subnet Mask | ||||||
GPIB | Optional: GUG-001 (GPIB to USB Adapter) | ||||||
Environmental Conditions | |||||||
Operating temperature | 0˚C to 50˚C | ||||||
Storage temperature | -25˚C to 70˚C | ||||||
Operating humidity | 20% to 85% RH; No condensation | ||||||
Storage humidity | 90% RH or less; No condensation | ||||||
Altitude | Maximum 2000m | ||||||
General Specifications | |||||||
Weight (main unit only) | kg | Approx. 3kg for 360W, Approx. 5.3kg for 720W, Approx. 7.5kg for 1080W |
|||||
Dimensions (WxHxD) | mm3 | 360W: 71×124×350mm, 720W: 142×124×350mm, 1080W: 214×124×350mm |
|||||
Cooling | Forced air cooling by internal fan. | ||||||
EMC | Complies with the European EMC directive 2004/108 /EC for Class A test and measurement products. | ||||||
Safety | Complies with the European Low Voltage Directive 2006 /95/EC and carries the CE-marking. | ||||||
Withstand voltage | Between input and chassis: No abnormalities at 1500 Vac for 1 minute. | ||||||
Between input and output: No abnormalities at 3000 Vac for 1 minute. | |||||||
Between output and chassis: No abnormalities at 500 Vdc for 1 minute for 30V, 80V, 160V models. |
|||||||
No abnormalities at 1500 Vdc for 1 minute for 250V, 800V models. | |||||||
Insulation resistance | Between input and chassis: 500 Vdc, 100MΩ or more | ||||||
Between input and output: 500 Vdc, 100MΩ or more | |||||||
Between output and chassis: 500 Vdc, 100MΩ or more for 30V, 80V, 160V and 250V models. |
|||||||
1000Vdc, 100MΩ or more for 800V models. | |||||||
Notes *1: At 85 ~ 132Vac or 170 ~ 265Vac, constant load. *2: From No-load to Full-load, constant input voltage. Measured at the sensing point in Remote Sense. *3: Measure with JEITA RC-9131B (1:1) probe *4: Measurement frequency bandwidth is 10Hz to 20MHz. *5: Measurement frequency bandwidth is 5Hz to 1MHz. *6: From 10% to 90% of rated output voltage, with rated resistive load. *7: From 90% to 10% of rated output voltage, with rated resistive load. *8: Time for output voltage to recover within 0.1% + 10mV of its rated output for a load change from 50 to 100% of its rated output current. *9: For load voltage change, equal to the unit voltage rating, constant input voltage. |
Tech Specs
Power Supplies/DC Power Supplies Template |
|
---|---|
Outputs | Single |
Voltage Output 1 | Variable |
Max Voltage Output 1 | 800 V |
Min Voltage Output 1 | 0 V |
Programmable | Yes |
Current Output 1 | Variable |
Max Current Output 1 | 2.88 A |
Min Current Output 1 | 0 A |
Meter Type | Digital |
Switching | Yes |
Linear/Switching | Switching |
Max Display Resolution Current | 1 mA |
Max Display Resolution Voltage | 14 mV |
Constant current/voltage | Yes |
Remote Sensing | Yes |
Test Equipment General Attributes |
|
Unique Features | Constant Power Output for Multiple Range (V&I) Operation CV/CC Priority; Particularly Suitable for the Battery and LED Industry Adjustable Slew Rate Bleeder Control Test Sequence Function Output On/Off delay function Series and Parallel Operation (2 units in Series / 3 units in Parallel Maximum) High Efficiency and High Power Density Labview Driver |