In Stock

Amprobe UAT-610 Underground Utility Locator Kit

Available for Quote

View List

Description

Accidentally hitting a utility line during a project can lead to costly repairs and create hazardous public safety situations. Digging in the wrong place can also lead to unnecessary delays and costs for your project, and ultimately, your company. Avoid this disruption with the rugged and durable Amprobe UAT-600 Series, designed to accurately pinpoint underground utilities and buried services up to 100 feet deep with accurate depth measurement to 20 feet.

Accidentally hitting a utility line during a project can lead to costly repairs and create hazardous public safety situations. Digging in the wrong place can also lead to unnecessary delays and costs for your project, and ultimately, your company. Avoid this disruption with the rugged and durable Amprobe UAT-600 Series, designed to accurately pinpoint underground utilities and buried services up to 100 feet deep with accurate depth measurement to 20 feet.

Quick Comparison

SettingsAmprobe UAT-610 Underground Utility Locator Kit removeAmprobe AT-2005-A Advanced Wire Tracer removeAmprobe AMB-110 Industrial High-Voltage Insulation Tester removeAmprobe AMB-50 Industrial High-Voltage Insulation Tester removeAmprobe PRM-6 Phase Sequence and Motor Rotation Tester removeAmprobe LM-120 Light Meter remove
Image
SKUN_Amprobe UAT-610N_Amprobe AT-2005-AN_Amprobe AMB-110_EBN_Amprobe_AMB-50N_Amprobe PRM-6N_Amprobe LM-120
Rating
PriceAvailable for QuoteAvailable for QuoteAvailable for QuoteAvailable for QuoteAvailable for QuoteAvailable for Quote
Stock
Availability
Add to cart

Add to Cart

Add to Cart

Add to Cart

Add to Cart

Add to Cart

Add to Cart

Description
ContentAccidentally hitting a utility line during a project can lead to costly repairs and create hazardous public safety situations. Digging in the wrong place can also lead to unnecessary delays and costs for your project, and ultimately, your company. Avoid this disruption with the rugged and durable Amprobe UAT-600 Series, designed to accurately pinpoint underground utilities and buried services up to 100 feet deep with accurate depth measurement to 20 feet. Accidentally hitting a utility line during a project can lead to costly repairs and create hazardous public safety situations. Digging in the wrong place can also lead to unnecessary delays and costs for your project, and ultimately, your company. Avoid this disruption with the rugged and durable Amprobe UAT-600 Series, designed to accurately pinpoint underground utilities and buried services up to 100 feet deep with accurate depth measurement to 20 feet.Like the AT-2004, the Amprobe AT-2005 Wire Tracer traces live wires buried or hidden behind walls up to 13 feet (4 m) thick without interrupting power. However, the AT-2005 electrical wire tracer also includes a battery booster that strengthens the signal for more accurately tracing opens and finding wires in walls. The AT-2005 is used for quickly locating breakers, broken wires, neutrals, grounds, shorts and pinpointing ground faults.Eliminate downtime, predict the lifetime of equipment and reduce safety hazards with the Amprobe AMB-110 Insulation Resistance Tester that tests voltage and step voltage to 10,000 V. You can accurately test cables, transformers, motors, surge arrestors and generators in noisy environments such as high voltage switchyards. It also boasts built-in noise rejection filters and shielded test leads to provide high EMI immunity.The Amprobe AMB-50 High-Voltage Insulation Tester has the necessary features for professional insulation diagnostics. It features calculation of PI and DAR parameters. The pass/fail comparison function helps to improve testing productivity. Readings are clearly displayed on a large backlit LCD display. Windows compatible PC Software and USB communications port serve for connecting the instrument to the PC and management of the recorded test data.If you install or connect 3-phase motors and systems, you recognize the importance of verifying the correct motor rotation and wiring phase sequence. Improper connections can cause motors to rotate in reverse direction, potentially damaging the motor and the equipment it is powering.The Amprobe LM-120 light meter measures the visible light from fluorescent, metal halide, high-pressure sodium or incandescent sources. It is a portable, easy-to-use digital light meter designed for simple one-hand operation reading in Lumen (lux) or foot candle (fc) units. The LM-120 measures a wide range of light up to 20,000 fc or 200,000 lux with an accurate, high resolution of 0.01 fc/lux. This unit is Auto-ranging plus manual ranging with ability to Zero out the reading before taking a measurement.
Weight10815611
Dimensions32 × 14 × 5 in19.9 × 17.2 × 12.5 in14 × 10 × 15 in10 × 8 × 4.5 in4 × 10 × 2 in4 × 10 × 2 in
Additional information
Weight 10 lbs
Dimensions 32 × 14 × 5 in
Weight 8 lbs
Dimensions 19.9 × 17.2 × 12.5 in
Weight 15 lbs
Dimensions 14 × 10 × 15 in
Weight 6 lbs
Dimensions 10 × 8 × 4.5 in
Weight 1 lbs
Dimensions 4 × 10 × 2 in
Weight 1 lbs
Dimensions 4 × 10 × 2 in