In Stock

Amprobe AMB-55 Industrial High-Voltage Insulation Tester

Available for Quote

View List

Description

Eliminate downtime, predict the lifetime of equipment and reduce safety hazards with the Amprobe AMB-55 Insulation Resistance Tester that tests voltage and step voltage to 5,500 V. You can accurately test cables, transformers, motors, surge arrestors and generators in noisy environments such as high voltage switchyards. It also boasts built-in noise rejection filters and shielded test leads to provide high EMI immunity

Quick Comparison

SettingsAmprobe AMB-55 Industrial High-Voltage Insulation Tester removeAmprobe AT-7020 Advanced Wire Tracer Kit removeAmprobe TMA-21HW Hotwire Anemometer with Temperature removeAmprobe AT-6000-R Wire Tracer Receiver with Back Light LCD Display removeAmprobe AT-6000-T Transmitter removeAmprobe GP-2A Ground Resistance Resistivity Tester remove
Image
SKUN_Amprobe AMB-55N_Amprobe AT-7020N_Amprobe TMA-21HWN_Amprobe AT-6000-RN_Amprobe AT-6000-TN_Amprobe GP-2A
Rating
PriceAvailable for QuoteAvailable for QuoteAvailable for QuoteAvailable for QuoteAvailable for QuoteAvailable for Quote
Stock
Availability
Add to cart

Add to Cart

Add to Cart

Add to Cart

Add to Cart

Add to Cart

Add to Cart

Description
ContentEliminate downtime, predict the lifetime of equipment and reduce safety hazards with the Amprobe AMB-55 Insulation Resistance Tester that tests voltage and step voltage to 5,500 V. You can accurately test cables, transformers, motors, surge arrestors and generators in noisy environments such as high voltage switchyards. It also boasts built-in noise rejection filters and shielded test leads to provide high EMI immunityThe AT-7020 Advanced Wire Tracer kit includes the AT-7000-R Receiver and the AT-7000-T Transmitter. The Receiver includes Amprobe?s patented Smart Sensor feature to instantly display the location and orientation of energized wires in walls, floors, and ceilings. You can clearly see the direction of the wire on the large, bright TFT LCD full color display. In hard-to-reach areas, you can use the Receiver?s Tip Sensor to trace wires in corners, tight spaces and junction boxes. The Transmitter offers two automatically-selected frequency modes for optimal tracing on energized and de-energized circuits, and three power modes (high, low, clamp) for a variety of environments. The breaker mode?s Scan and Locate feature identifies the one correct breaker or fuse with the highest recorded signal, thus eliminating the confusion of multiple false positives common with older technology tracing tools. So whether you?re a novice user or an expert, this Amprobe circuit tracer kit will help you get the job done fast.The Amprobe TMA-21HW Hotwire anemometer technology eliminates the use of bearings and rotating parts. When compared to standard bearing type probes, the compact Amprobe hotwire sensor is more reliable (no mechanical moving parts) and allows for easier access to duct and confined spaces. The Amprobe TMA-21HW Hotwire anemometer measures air flow volume and velocity, it features a telescopic probe for positioning the sensor, and is used by HVAC/R technicians to measure wind flow and temperature in air conditioning systems.Amprobe?s advanced wire tracer technology combines a Receiver and powerful Transmitter to locate energized and de-energized wires, breakers, and fuses without having to disconnect any equipment. The Receiver features four tracing modes optimized for a range of applications, and the Transmitter utilizes two optimized frequencies that allows for a clean and reliable signal. Whether you?re a novice user or an expert, the AT-6000 Advanced Wire Tracer Series kits will help you get the job done fast.The AT-6000-T Transmitter works on Energized and De-energized circuits up to 600 V AC/DC in Category I through Category III electrical environments and features high signal, low signal, and loop modes. The Breaker Identification feature eliminates confusion of multiple false positives, common with older technology tracing tools, by identifying the one correct breaker or fuse with the highest recorded signal.Poor grounding is dangerous and contributes to unnecessary downtime and increases the risk of equipment failure. The Amprobe GP-2A Earth Ground Resistance Tester provides accurate and reliable measurements for ground resistance and soil resistivity to assure the safety and performance of an electrical system. The GP-2A is complete with PC software that allows the user to download critical recorded measurements and to create professional reports for customers.
Weight1552112
Dimensions17.3 × 5.8 × 13 in17.3 × 14.3 × 8.8 in14 × 11.4 × 3.7 in9.5 × 6.5 × 1.75 in9.5 × 6.5 × 1.75 in12.4 × 8.3 × 6.6 in
Additional information
Weight 15 lbs
Dimensions 17.3 × 5.8 × 13 in
Weight 5 lbs
Dimensions 17.3 × 14.3 × 8.8 in
Weight 2 lbs
Dimensions 14 × 11.4 × 3.7 in
Weight 1 lbs
Dimensions 9.5 × 6.5 × 1.75 in
Weight 1 lbs
Dimensions 9.5 × 6.5 × 1.75 in
Weight 2 lbs
Dimensions 12.4 × 8.3 × 6.6 in