In Stock

Kikusui PLZ664WA Electronic Loads 0-150V 0-132A, 660W

Available for Quote

Kikusui’s new PLZ664WA Series Electronic Loads feature faster rise/fall times with variable slew rates for transient testing on high speed DC/DC convertors and DC power supplies. WA versions offer 0V inputs even at maximum rated current input enabling testing of single cell fuel cells. Test modes are constant current, constant resistance, constant voltage, constant power, or a combination of these modes. Current setting resolution can be as low as 0.1mA. Sequence function permits 10 sequence patterns to be saved in the built in memory. Battery cell discharge times from load on to load off can be measured. Other functions include soft start, short, ABC memory, set up memory, switching. PLZ4W has GPIB (SCPI compatible), RS232c and USB as standard.

1 in stock

View List
SKU: Kikusui PLZ664WA Category: Tag:

Quick Comparison

SettingsKikusui PLZ664WA Electronic Loads 0-150V 0-132A, 660W removeGW Instek PEL-2030 Programmable DC Electronic Load Dual Channel Module, (1~80V, 5A, 30W) + (1~80V, 40A, 250W) removeGW Instek PEL-2040 Programmable DC Electronic Load Single Channel Module, (1~80V, 70A, 350W) removeAgilent 60504B Electronic Load Module 600 Watt, 60V, 60A removeAgilent 6051A 600 Watt DC Electronic Load Mainframe removeGW INSTEK PEL-3211 DC LOAD, PROGRAMMABLE, 420A, 1.5-150V, 2.1KW remove
Image
SKUKikusui PLZ664WAN_GW Instek PEL-2030AN_GW Instek PEL-2040AAgilent 60504BAgilent 6051AN_GW Instek PEL-3211
Rating
PriceAvailable for QuoteAvailable for QuoteAvailable for QuoteAvailable for QuoteAvailable for QuoteAvailable for Quote
Stock

1 in stock

1 in stock

1 in stock

Availability1 in stock1 in stock1 in stock
Add to cart

Add to Cart

Add to Cart

Add to Cart

Add to Cart

Add to Cart

Add to Cart

DescriptionKikusui's new PLZ664WA Series Electronic Loads feature faster rise/fall times with variable slew rates for transient testing on high speed DC/DC convertors and DC power supplies. WA versions offer 0V inputs even at maximum rated current input enabling testing of single cell fuel cells. Test modes are constant current, constant resistance, constant voltage, constant power, or a combination of these modes. Current setting resolution can be as low as 0.1mA. Sequence function permits 10 sequence patterns to be saved in the built in memory. Battery cell discharge times from load on to load off can be measured. Other functions include soft start, short, ABC memory, set up memory, switching. PLZ4W has GPIB (SCPI compatible), RS232c and USB as standard.The PEL-2000A Series includes two types of mainframes and 4 types of load modules to accommodate users' requirements in a flexible manner. Any load module combination can be used with a mainframe to tailor a test system based on the number of channels, and the maximum load power, voltage and current of each channel. Multiple loads can be connected in parallel to provide a higher-power load to test higher power supply outputs. This flexibility significantly reduces the investment needed for future projects that have different power requirements. The PEL-2004A is a 4-slot mainframe with a master control unit to hold 4 load modules, while PEL-2002A is a 2-slot mainframe with master control unit to hold 2 load modules. When the PEL-2004A is configured with 4 load modules rated at 350W each, the PEL-2000A series is able to sink up to 1.4kVA of power.The PEL-2000A Series includes two types of mainframes and 4 types of load modules to accommodate users' requirements in a flexible manner. Any load module combination can be used with a mainframe to tailor a test system based on the number of channels, and the maximum load power, voltage and current of each channel. Multiple loads can be connected in parallel to provide a higher-power load to test higher power supply outputs. This flexibility significantly reduces the investment needed for future projects that have different power requirements. The PEL-2004A is a 4-slot mainframe with a master control unit to hold 4 load modules, while PEL-2002A is a 2-slot mainframe with master control unit to hold 2 load modules. When the PEL-2004A is configured with 4 load modules rated at 350W each, the PEL-2000A series is able to sink up to 1.4kVA of power.The Keysight 6051A electronic load mainframe accepts user-installable Keysight load modules for easy system configuration and future reconfiguration. The 6051A holds up to two 60501B, 60502B, 60503B modules, or one 60504B or 60507B module allowing up to 600 watts of total maximum power. One GPIB address is all you need for complete control and readback of all modules within a single mainframe.2100 W Booster Unit [for use with PEL-3111 only]
Content
Weight353636321516
Dimensions8 × 18 × 18 in10 × 24 × 12 in10 × 24 × 12 in8 × 10 × 26 in8 × 10 × 26 in10 × 24 × 12 in
Additional information
Weight 35 lbs
Dimensions 8 × 18 × 18 in
Weight 36 lbs
Dimensions 10 × 24 × 12 in
Weight 36 lbs
Dimensions 10 × 24 × 12 in
Weight 32 lbs
Dimensions 8 × 10 × 26 in
Weight 15 lbs
Dimensions 8 × 10 × 26 in
Weight 16 lbs
Dimensions 10 × 24 × 12 in