GPT-9500 Multi-Channel Hipot Tester
Features
- 150VA AC Test Capacity
- 3 in 1 Tester : AC, DC, IR
- Built-in 8 channel Scanner
- 480 x 272 Color TFT LCD
- Test parameter Export / Import through USB host
- Statistics (counter) function
- Insulation resistance measurement up to 10GΩ
- Open/Short Check (OSC)
- ARC detection
- Multi-language: Traditional / Simplified Chinese、English
- Interface: RS-232C and USB host/device
GW Instek introduces a new multi-channel withstanding voltage tester-the GPT-9500 series. This series has 2 models and each model has a built-in 8-channel scanner. The series meets safety regulations: IEC, EN, UL, CSA, GB, JIS and other safety regulations. The series aims at the needs of the main test items of general electronic components or winding components during routine tests.
The GPT-9500 series is a three-in-one multi-channel tester, providing AC withstanding voltage (5kV max.), DC withstanding voltage (6kV max.), and insulation resistance (1000V max.). The design of the series conforms to the latest IEC-61010-2-034 standard requirements and it is built on the output platform of AC 150VA. The status of the 8 channels of GPT-9513 can be set to H, L or X according to the test requirements, especially suitable for winding components such as transformers to perform mutual testing of multiple points of single components. The status of the 8 channels of GPT-9503 only provides the setting of H or X, which is more suitable for general components such as passive components for high-voltage testing between two points.
Extend Your Tests
- Meets IEC 61010-2-034 design requirements
- Bulit-in 8 channel Scanner
- Test parameter Export / Import through USB host
- Statistic (counter) function
Manufacturer Specs
AC WITHSTANDING Output-Voltage Range
Output-Voltage Resolution
Output-Voltage Accuracy
Maximum Rated Load
Maximum Rated Current
Output-Voltage Waveform
Voltage Regulation
Output-Voltage Frequency
Voltmeter Accuracy
Current Measurement Range
Current Best Resolution
Current Measurement Accuracy
Current Offset
ARC Detect
RAMP TIME (Rise Time)
FALL Time
WAIT Time
TIMER (Test Time)
TIMER Accuracy
GND 0.050kV ~ 5.000kV
1V
±(1% of setting + 5V) [no load]
150 VA (5kV/30mA)
30mA ; 0.001mA ~ 10mA (0.05kV≦V≦0.5kV) ; 0.001mA ~ 30mA (0.5kV< V≦5kV)
Sine wave
50 Hz / 60 Hz selectable
±(1% + 5V) [maximum rated load → no load]
±(1% of reading + 5V)
0.001mA ~ 30.00mA
1μA (0.001mA ~ 9.999mA) ; 10μA (10.00mA ~ 30.00mA)
±(1.5% of reading + 30μA)
80μA maximum
Yes
0.1s~999.9s
OFF~999.9s
OFF~999.9s
CONT, 0.3s~999.9s
±(100ppm + 20ms)
ON/OFF DC WITHSTANDING Output-Voltage Range
Output-Voltage Resolution
Output-Voltage Accuracy
Maximum Rated Load
Maximum Rated Current
Voltmeter Accuracy
Voltage Regulation
Current Measurement Range
Current Best Resolution
Current Measurement Accuracy
Current Offset
ARC Detect
RAMP TIME (Rise Time)
FALL Time
WAIT Time
TIMER (Test Time)
TIMER Accuracy
GND 0.050kV~6.000kV
1V
±(1% of setting + 5V) [no load]
50W (5kV/10mA)
10mA ; 0.001mA ~ 2mA (0.05kV≦ V ≦0.5kV); 0.001mA ~ 10mA (0.5kV< V ≦6kV)
±(1% + 5V) [maximum rated load → no load]
±(1% of reading + 5V)
0.001mA ~ 10.00mA
0.1μA (0.1μA ~ 999.9μA) ; 1μA (1μA ~ 9.999mA) ; 10μA (10.00mA)
±(1% of reading + 1μA) when I Reading < 1mA ; ±(1% of reading + 10μA) when I Reading≦1mA
5μA maximum
Yes
0.1s~999.9s
OFF~999.9s
OFF~999.9s
CONT, 0.3s~999.9s
±(100ppm + 20ms)
ON/OFF INSULATION RESISTANCE Output Voltage
Output-Voltage Resolution
Output-Voltage Accuracy
Resistance Measurement
Test Voltage
50V≦V<500V
500V≦V≦1000V
Voltage Regulation
Voltmeter Accuracy
Short-Circuit Current
Output Impedance
RAMP TIME (Rise Time)
FALL Time
WAIT TIME
TIMER (Test Time)
TIMER Accuracy
GND 50V~1000V dc
1V
± (1% of setting + 5V) [no load]
0.1MΩ~10GΩ
Measurement Range / Accuracy
0.1MΩ~1MΩ:±(5% of reading + 3 count); 1 MΩ~50MΩ:±(5% of reading + 1 count);
51MΩ~2GΩ:±(10% of reading + 1 count)
0.1MΩ~1MΩ:±(5% of reading + 3 count); 1 MΩ~500MΩ:±(5% of reading + 1 count);
501MΩ~10GΩ:±(10% of reading + 1 count)
± (1% + 5V) [maximum rated load → no load]
± (1% of reading + 5V)
10mA max.
2kΩ
0.1s~999.9s
OFF~999.9s
OFF~999.9s
0.3s~999.9s
±(100ppm + 20ms)
ON/OFF CONTINUITY TEST Output-Current Ohmmeter
Measurement Accuracy 100mA dc
1Ω ± 0.2Ω, ON/OFF INTERFACE Signal I/O
RS-232C
USB (Device)
USB (Host)
Rear Output Standard
Standard
Standard
Standard (for Parameter/LCD Hardcopy)
Scanner DISPLAY 4.3″ Color LCD POWER SOURCE AC 100V~240V ± 10%, 50Hz/60Hz DIMENSIONS & WEIGHT 320(W) x 120(H) x 435(D) mm; Approx. 11kg
AC WITHSTANDING | Output-Voltage Range Output-Voltage Resolution Output-Voltage Accuracy Maximum Rated Load Maximum Rated Current Output-Voltage Waveform Voltage Regulation Output-Voltage Frequency Voltmeter Accuracy Current Measurement Range Current Best Resolution Current Measurement Accuracy Current Offset ARC Detect RAMP TIME (Rise Time) FALL Time WAIT Time TIMER (Test Time) TIMER Accuracy GND | 0.050kV ~ 5.000kV 1V ±(1% of setting + 5V) [no load] 150 VA (5kV/30mA) 30mA ; 0.001mA ~ 10mA (0.05kV≦V≦0.5kV) ; 0.001mA ~ 30mA (0.5kV< V≦5kV) Sine wave 50 Hz / 60 Hz selectable ±(1% + 5V) [maximum rated load → no load] ±(1% of reading + 5V) 0.001mA ~ 30.00mA 1μA (0.001mA ~ 9.999mA) ; 10μA (10.00mA ~ 30.00mA) ±(1.5% of reading + 30μA) 80μA maximum Yes 0.1s~999.9s OFF~999.9s OFF~999.9s CONT, 0.3s~999.9s ±(100ppm + 20ms) ON/OFF |
DC WITHSTANDING | Output-Voltage Range Output-Voltage Resolution Output-Voltage Accuracy Maximum Rated Load Maximum Rated Current Voltmeter Accuracy Voltage Regulation Current Measurement Range Current Best Resolution Current Measurement Accuracy Current Offset ARC Detect RAMP TIME (Rise Time) FALL Time WAIT Time TIMER (Test Time) TIMER Accuracy GND | 0.050kV~6.000kV 1V ±(1% of setting + 5V) [no load] 50W (5kV/10mA) 10mA ; 0.001mA ~ 2mA (0.05kV≦ V ≦0.5kV); 0.001mA ~ 10mA (0.5kV< V ≦6kV) ±(1% + 5V) [maximum rated load → no load] ±(1% of reading + 5V) 0.001mA ~ 10.00mA 0.1μA (0.1μA ~ 999.9μA) ; 1μA (1μA ~ 9.999mA) ; 10μA (10.00mA) ±(1% of reading + 1μA) when I Reading < 1mA ; ±(1% of reading + 10μA) when I Reading≦1mA 5μA maximum Yes 0.1s~999.9s OFF~999.9s OFF~999.9s CONT, 0.3s~999.9s ±(100ppm + 20ms) ON/OFF |
INSULATION RESISTANCE | Output Voltage Output-Voltage Resolution Output-Voltage Accuracy Resistance Measurement Test Voltage 50V≦V<500V 500V≦V≦1000V Voltage Regulation Voltmeter Accuracy Short-Circuit Current Output Impedance RAMP TIME (Rise Time) FALL Time WAIT TIME TIMER (Test Time) TIMER Accuracy GND | 50V~1000V dc 1V ± (1% of setting + 5V) [no load] 0.1MΩ~10GΩ Measurement Range / Accuracy 0.1MΩ~1MΩ:±(5% of reading + 3 count); 1 MΩ~50MΩ:±(5% of reading + 1 count); 51MΩ~2GΩ:±(10% of reading + 1 count) 0.1MΩ~1MΩ:±(5% of reading + 3 count); 1 MΩ~500MΩ:±(5% of reading + 1 count); 501MΩ~10GΩ:±(10% of reading + 1 count) ± (1% + 5V) [maximum rated load → no load] ± (1% of reading + 5V) 10mA max. 2kΩ 0.1s~999.9s OFF~999.9s OFF~999.9s 0.3s~999.9s ±(100ppm + 20ms) ON/OFF |
CONTINUITY TEST | Output-Current Ohmmeter Measurement Accuracy | 100mA dc 1Ω ± 0.2Ω, ON/OFF |
INTERFACE | Signal I/O RS-232C USB (Device) USB (Host) Rear Output | Standard Standard Standard Standard (for Parameter/LCD Hardcopy) Scanner |
DISPLAY | 4.3″ Color LCD | |
POWER SOURCE | AC 100V~240V ± 10%, 50Hz/60Hz | |
DIMENSIONS & WEIGHT | 320(W) x 120(H) x 435(D) mm; Approx. 11kg |
Included Accessories
Quick Start Guide x1, CD x1(completed user manual),
Power cord x1,
Test lead GHT-115 x1, GHT-116B x1, GHT-116R x8
Optional Accessories
GTL-236 RS232C Cable, approx. 2m
GTL-246 USB Cable, A-B type, approx. 1.2m