In Stock

Instek GLN-5040A Line Impedance Stabilization Networ – Line Impedance Stabilization Network [LISN] for GSP-9330 spectrum analyzer

Available for Quote

The GLN – 5040A Two Line V – Network is used for EMI testing. It provides stable impedance for the EUT terminals and the reference ground within the conducted emissions range. The GLN – 5040A also isolates the unwanted network signals from the power supply unit and only couples the disturbance voltage of the measured device to the receiver. The product’s performance is in compliance with the standard requirements of CISPR16 – 1 – 2 for V – networks with a simulated impedance of 50? H + 5 ?) || 50 ? in the frequency range of 9kHz to 30MHz. It uses standard BNC output connector with 50 ? output impedance to match any measurement devices such as receivers and spectrum analyzers.

View List
SKU: N_GW Instek GLN-5040A Category: Tag:

Quick Comparison

SettingsInstek GLN-5040A Line Impedance Stabilization Networ - Line Impedance Stabilization Network [LISN] for GSP-9330 spectrum analyzer removeGW Instek GPE-1326 Multi-Output DC Power Supply, Single Channel, 192W, 0-32 VDC, 0-6A removeInstek PLR 36-10 DC Power Supply, 36V, 10A, 360W Low Noise removeGW Instek GPE-3323 GPE-X323 Multi-Output DC Power Supply, 3 Channel, 217W, 0-32 VDC, 0-3A, 5V/5A removeInstek GPS-4303 200W Quadruple-Output Linear DC Power Supply, 30V DC, 3 Amp removeInstek GPD-4303S 200W Quadruple-Output Programmable Linear DC Power Supply, 30V DC, 3 Amp, 1mV, 1-milliamp Resolution remove
Image
SKUN_GW Instek GLN-5040AN_GW Instek GPE-1326N_GW Instek PLR 36-10N_GW Instek GPE-3323N_GW Instek GPS-4303N_GW Instek GPD-4303S
Rating
PriceAvailable for QuoteAvailable for QuoteAvailable for QuoteAvailable for QuoteAvailable for QuoteAvailable for Quote
Stock
Availability
Add to cart

Add to Cart

Add to Cart

Add to Cart

Add to Cart

Add to Cart

Add to Cart

DescriptionThe GLN - 5040A Two Line V - Network is used for EMI testing. It provides stable impedance for the EUT terminals and the reference ground within the conducted emissions range. The GLN - 5040A also isolates the unwanted network signals from the power supply unit and only couples the disturbance voltage of the measured device to the receiver. The product's performance is in compliance with the standard requirements of CISPR16 - 1 - 2 for V - networks with a simulated impedance of 50? H + 5 ?) || 50 ? in the frequency range of 9kHz to 30MHz. It uses standard BNC output connector with 50 ? output impedance to match any measurement devices such as receivers and spectrum analyzers.192W Single Channel DC Power Supply GPE-1326 Single Channel, 192W Linear DC Power Supply 1 Independent Isolated Output 10mv min resolution 1ma min resolution 4.3 Inch LCD Display Setting & Read back Resolution 10mA / 1mA Output ON/OFF Analog Control (Remote I/O) for Output ON / OFF Set View function for checking an original V / I setting during output on Key Lock Function Tracking series and parallel operation Smart cooling fan achieving low noise Optional European Jack Type Terminal

Hybrid Linear, Low noise, 0-36V/0-10A, 360W

  • Output Voltage Rating: 36V
  • Output Power: 360W
  • Low Ripple and Noise (0.5mVrms/ 10mArms)
  • Fast transition recovery time (100us)
  • Maximum 2 units in series connections or 3 units in parallel connections
  • Select the setting digits for voltage and current (coarse/ fine volume control)
  • Panel Lock Function
  • 3 set of preset function
  • Output off timer function (Range: 1min to 1000hours & 59mins)
  • CC priority function (prevent overshoot & inrush current)
  • Sequence function of PC editing (Max.: 1000 steps/ Min. step period: 50ms)
  • Protection: OVP, UVP, OCP, remote sensing (Terminal open)
  • External Analog Control Function
  • PC Remote Interface (Standard): RS-232; (Optional): GPIB / USB / LAN
  • CE Compliance
217W 3 Channel DC Power Supply GPE-3323 3 Channels, 217W Linear DC Power Supply 3 Independent Isolated Output 10mv min resolution 1ma min resolution 4.3 Inch LCD Display Setting & Read back Resolution 10mA / 1mA Output ON/OFF Analog Control (Remote I/O) for Output ON / OFF Set View function for checking an original V / I setting during output on Key Lock Function Tracking series and parallel operation Smart cooling fan achieving low noise Optional European Jack Type Terminal195W, 4ch Output DC Programmable Power Supply 4 Outputs for GPD-4303S High Resolution Display 1mV / 1mA (GPD-X303S) CH1/CH2 Output: 30V / 3A CH3 Selectable Output: 5V/3A ; 5.001V-10V /1A (GPD-4303S) CH4 Output: 5V / 1A (GPD-4303S) Auto Series / Parallel Tracking Mode Digital Panel ControlRotary Encoder Switch and Rubber Key with Backlight 4 Sets SAVE / RECALL panel setting User Friendly Operation, Coarse and Fine Voltage Control Warring Buzzer Output On / Off Switch USB Device for Remote Control (Baud Rate 115200 bps Maximum) Free downloadable PC software Smart Cooling Fan with Low Noise Safety Design: Reverse Polarity, Overload Protection
Content
Weight121515151518
Dimensions23 × 18 × 11 in20 × 15 × 11 in18 × 12 × 10 in18 × 12 × 10 in18 × 12 × 10 in22 × 15 × 12 in
Additional information
Weight 12 lbs
Dimensions 23 × 18 × 11 in
Weight 15 lbs
Dimensions 20 × 15 × 11 in
Weight 15 lbs
Dimensions 18 × 12 × 10 in
Weight 15 lbs
Dimensions 18 × 12 × 10 in
Weight 15 lbs
Dimensions 18 × 12 × 10 in
Weight 18 lbs
Dimensions 22 × 15 × 12 in