In Stock

Data Logger Model DL-1081 (8 Analog to 8 Digital Channel, Display)

Available for Quote

The 8-Channel Data Logger Model DL-1081 with display is a versatile, powerful and cost effective data logger handling analog, digital and other types of variables with high resolution and speed. It offers high performance and is easy to configure and operate. The Model DL-1081 has 8 configurable analog inputs that can measure thermocouples, Pt100, Pt1000, DC voltage and DC current signals. It is equipped with 2 relay outputs and 8 digital ports that are individually configurable as inputs or outputs. Up to 128 math channels can be used to perform operations on the measured values. Up to 32 alarm events can be detected, allowing output activations, e-mails and SNMP trap sending. The RS485 interface can operate as a Modbus RTU master or slave. As a master, it can read and log up to 64 external channels. A 10/100Mbps Ethernet interface allows access through a browser HTTP, FTP client and server, e-mails sending SMTP, SNMP and Modbus TCP.

View List
SKU: N_AEMC DL-1081 Category: Tag:

Quick Comparison

SettingsData Logger Model DL-1081 (8 Analog to 8 Digital Channel, Display) removeCalibration of AEMC 4620 Ground Resistance Tester NIST Calibration with Certificate removeAEMC 6416 Ground Resistance Tester removeAEMC 6418 Ground Resistance Tester removeClamp-on Meter Model 670 (Dual Display, TRMS, AC Amps, AC/DC Volts, Ohms, Continuity, Frequency, & Temperature) removeClamp-on Meter Model 203 (TRMS, 1000VAC/DC, 600AAC/900ADC, Ohms, Continuity, Temperature) remove
Image
SKUN_AEMC DL-1081C_AEMC 4620N_AEMC 6416N_AEMC 6418N_AEMC 670N_AEMC 203
Rating
PriceAvailable for QuoteAvailable for QuoteAvailable for QuoteAvailable for QuoteAvailable for QuoteAvailable for Quote
Stock
Availability
Add to cart

Add to Cart

Instant Quote

Add to Cart

Add to Cart

Add to Cart

Add to Cart

DescriptionThe 8-Channel Data Logger Model DL-1081 with display is a versatile, powerful and cost effective data logger handling analog, digital and other types of variables with high resolution and speed. It offers high performance and is easy to configure and operate. The Model DL-1081 has 8 configurable analog inputs that can measure thermocouples, Pt100, Pt1000, DC voltage and DC current signals. It is equipped with 2 relay outputs and 8 digital ports that are individually configurable as inputs or outputs. Up to 128 math channels can be used to perform operations on the measured values. Up to 32 alarm events can be detected, allowing output activations, e-mails and SNMP trap sending. The RS485 interface can operate as a Modbus RTU master or slave. As a master, it can read and log up to 64 external channels. A 10/100Mbps Ethernet interface allows access through a browser HTTP, FTP client and server, e-mails sending SMTP, SNMP and Modbus TCP.All equipment calibrations do not include any equipment warranty. Equipment that has any visible sign of damage will be documented and the customer will be notified before any services are performed. Any needed repairs will be quoted separately. All of our items will ship with Warranty Void tamper resistant seals. If these seals have been removed or tampered with, the Calibration will be void.The Clamp-on Meter Model 670 is a general purpose professional clamp-on meter offering a complete set of measurement ranges, AC current, AC and DC voltage, resistance, continuity with beeper, frequency from V or A, and temperature. It is in compliance with international safety and quality standards ensuring you have the most professional and reliable measuring tool. This meter is designed to measure and display amps and volts at the same time. It also is auto-ranging and provides the best measurement range and resolution for troubleshooting.
ContentThe Ground Resistance Tester Model 6416 measures ground rod and grid resistance and impedance without the use of auxiliary rods. Clamp-on ground resistance testers can be used in multi-grounded systems without disconnecting or de-energizing the ground system under test. The Model 6416 simply clamps around the grounding electrode or conductor and measures the resistance to ground. By performing measurements on intact ground systems, the user also verifies the quality of the grounding connections and bonds. Resistance and continuity of grounding loops around pads and buildings may also be measured.The Ground Resistance Tester Model 6418 measures ground rod, busbar, and grid resistance and impedance without the use of auxiliary rods. Clamp-on ground resistance testers can be used in multi-grounded systems without disconnecting or de-energizing the ground system under test. The Model 6418 simply clamps around the grounding electrode or conductor and measures the resistance to ground. By performing measurements on intact ground systems, the user also verifies the quality of the grounding connections and bonds. Resistance and continuity of grounding loops around pads and buildings may also be measured.
Weight683.53.599
Dimensions6 × 6 × 6 in10 × 8 × 12 in12 × 5 × 5 in12 × 5 × 5 in6 × 6 × 12 in6 × 6 × 12 in
Additional information
Weight 6 lbs
Dimensions 6 × 6 × 6 in
Weight 8 lbs
Dimensions 10 × 8 × 12 in
Weight 3.5 lbs
Dimensions 12 × 5 × 5 in
Weight 3.5 lbs
Dimensions 12 × 5 × 5 in
Weight 9 lbs
Dimensions 6 × 6 × 12 in
Weight 9 lbs
Dimensions 6 × 6 × 12 in